Release Notes

Issue 15
Description: NIC Inventory field for Virtual MAC Address are displayed as "00:00:00:00:00:00", if Virtual MAC Address has not been
configured for the NIC. This issue affects the Dell Server and Rack Workstation Monitoring (Licensed) feature in version 6.3 and the
out-of-band or the agent based monitoring feature of versions 6.0 and later.
Resolution: None.
Version affected: Dell Server Management Pack Suite versions 6.0 and later.
Issue 16
Description: If no scope is selected in the Authoring Pane and Dell.DRAC.OM07 MP is imported, a Dialog Box with message “Object
not found” is displayed by OpsMgr. This issue affects the iDRAC monitoring for Dell Server Management Suite Pack versions 6.0 and
later.
Resolution: Close the Dialog Box. Select a scope target in the OpsMgr Authoring Pane.
Version affected: Dell Server Management Suite Pack versions 6.0 and later.
Issue 17
Description: While upgrading from SCOM 2007 (with Dell Chassis or iDRAC) to SCOM 2012,the auto-import of CMC(2012) and
DRAC(2012) MPs happens in the second discovery cycle after the upgrade. In a few cases successful upgrade occurs in the first cycle
itself. This issue affects the iDRAC monitoring for Dell Server Management Suite Pack versions 6.0 and later.
Resolution: Apply manually.
Version affected: Dell Server Management Suite Pack versions 6.0 and later.
Issue 18
Description: Overrides for CMC and DRAC devices if present in a single custom override MP do not get automatically transferred after
SCOM upgrading from 2007 R2 to 2012.
Resolution: Apply manually.
Version affected: All
Issue 19
Description: Server sub-component display names are displayed incorrectly. This issue affects the Dell Server and Rack Workstation
Monitoring (Licensed) for version 6.3 or the out-of-band monitoring feature for Dell Server Management Suite Pack versions 6.0, 6.1,
and 6.2.
Resolution: None.
Version affected: Dell Server Management Pack Suite versions 6.0 and later.
Issue 20
Description: While upgrading of DRAC MP from v4.1 to v5.0, FMP is designed to transfer all the overrides from DRAC 4.1 MP to DRAC
5.0 MP specific. When the overrides are for the base class "iDRAC", it is mapped to "iDRAC6Monolithic" class alone. The mapping is
not done for the "iDRAC6Modular" class. This issue affects the iDRAC monitoring for Dell Server Management Suite Pack versions 6.0
and later.
Resolution: Apply manually.
Version affected: Dell Server Management Pack Suite versions 6.0 and later.
Issue 21
Description: The Fan components of the Dell PowerEdge M1000e chassis are displayed as ‘Dell Fan’.
Resolution: Upgrade the Dell PowerEdge M1000e firmware to version 5.0.1
Version affected: All
Issue 22
Description: Even after removing the power supply module, the overall enclosure sensor status may still be displayed as Healthy. This
issues affects the Dell Server and Rack Workstation Monitoring for version 6.3 or the agent-based monitoring feature for versions 6.0,
6.1, and 6.2.
Resolution: None
Version affected: Dell Server Management Pack Suite versions 6.0 and later.
Issue 23
Description: In Chassis inventory, the IP address may not be updated for the IO module. This issue affects the Chassis Monitoring
(Detailed) feature for CMC version 5.0.1.
Resolution: None.
Dell Server Management Pack Suite Version 6.3 for Microsoft System Center Operations Manager Release Notes
9