Release Notes
Table Of Contents
Version affected: Dell Server Management Pack Suite versions 6.0 and later.
• Issue 7
Description: Temporary files are not removed when the RACADM tool fails. When remote RACADM takes a long time to get server
module or free slot information from a Dell Chassis, SCOM may terminate the "CMC Slot Discovery" scripts. As a result, you will see
"Script or Executable failed to Run" alert in the SCOM Alerts View and some files will be left over in the
%windir%\Temp
\ChassisRemoteAccess_Logs directory in the management station managing the Dell Chassis. This issue affects the Chassis
monitoring feature in versions 6.0 and later.
Resolution: Remove the temporary files manually.
Version affected: Dell Server Management Pack Suite versions 6.0 and later.
• Issue 8
Description: On SCOM 2007 R2 distributed setups, though an FMP task is completed functionally and the Task History is displayed
this as complete, occasionally SCOM may still continue to have the task popup in running state. This issue affects the Feature
Management in versions 6.0 and later.
Resolution: Close the task popup window.
Version affected: Dell Server Management Pack Suite versions 6.0 and later.
• Issue 9
Description: Despite updating the default port number, CMC or DRAC running firmware version 3.0 returns the wrong URL. This issue
affects the iDRAC and the Chassis monitoring features in versions 6.0 and later.
Resolution: None.
Version affected: Dell Server Management Pack Suite versions 6.0 and later.
• Issue 10
Description: Servers discovered through the Server and Rack Workstation Monitoring feature are shown with the default logical
device icon. This issue affects the Dell Server and Rack Workstation Monitoring feature in version 6.3 and the In-band or the agent
based monitoring feature of versions 6.0 and later.
Resolution: None.
Version affected: Dell Server Management Pack Suite versions 6.0 and later.
• Issue 11
Description: When the Dell Server Management Pack Suite is installed on one of the management servers of a distributed setup,
workflows may have propagated to the other management servers that expect the Dell Device Helper utility to be present. This
generates a Warning event in both Operations Manager console andWindows event log with id 21406. This may also be seen during
the uninstallation of Dell Server Management Pack Suite.
Resolution: If required, install Dell Server Management Pack Suite on the remaining management servers of the distributed setup, for
more information see the Dell Server Management Pack Suite Version 6.3 for Microsoft System Center Operations Manager
Installation Guide. Otherwise, ignore the alerts.
Version affected: All.
• Issue 12
Description: If the component is under a Software RAID controller, Inventory for Bus Type and Media Protocol in Virtual Disk is not
supported.
Resolution: Please see the iDRAC documentation for updated support.
Version affected: All.
• Issue 13
Description: Inventory field Manufacturer for SATA Disks may be incorrectly reported as "ATA". This issue affects the Dell Server and
Rack Workstation Monitoring (Licensed) feature in version 6.3 and the out-of-band or the agent based monitoring feature of versions
6.0 and later.
Resolution: None
Version affected: Dell Server Management Pack Suite versions 6.0 and later.
• Issue 14
Description: Unit Monitors for Memory Group Redundancy are disabled. This issue affects the Dell Server and Rack Workstation
Monitoring feature in version 6.3 and the in-band or the agent based monitoring feature of versions 6.0 and later.
Resolution: None.
Version affected: Dell Server Management Pack Suite versions 6.0 and later.
8
Dell Server Management Pack Suite Version 6.3 for Microsoft System Center Operations Manager Release Notes