Install Guide
• To monitor Chassis controller, IO Module, IO Module Group, Power Supply, and Power Supply Group components; enable
RACADM utility. RACADM utility is now required only to monitor the health of Chassis controller, IO Module, IO Module Group,
Power Supply, and Power Supply Group components.
• To monitor the health of Chassis devices, associate the community string Run As account with the SNMP Monitoring Account
with the target as Dell Modular Chassis class or respective Chassis object (if you have different Run As accounts for different
Chassis devices).
• To discover Chassis Slots and Chassis Slot Summary for CMC; create Run As Accounts and associate it to the profiles — Dell
CMC Login Account Run As Profiles. Also, enable the CMC Slot Discovery from the OpsMgr console. For more information,
see Configuring Dell Chassis Management Controller feature for Correlating Server Modules with Chassis Slot Summary.
• To perform Chassis Detailed monitoring; create Run As Accounts with WS-MAN credentials required for accessing the Dell
CMCs, and associate it to the profiles — Dell CMC Login Account Run As Profiles.
NOTE:
• If you are using AD domain credentials for CMC, then, enter the credentials in the following format:
username@domainname.com
Configuring Dell Chassis Management Controller feature for
Correlating Server Modules with Chassis Slot Summary
To configure CMC feature for correlating server modules, create Run As Accounts and associate it to Run As Profiles to populate
chassis slot summary.
1. Create a Run As Account of type Simple Authentication that has privileges to connect to the CMC module on the chassis.
Also, use Basic or Digest Run As Account types for configuring the user credentials.
2. Select the More Secure or Less Secure option in Run As Account configuration, so that you can selectively distribute the
configuration to specific management servers.
For information on creating a Run As Account of type Simple Authentication, see the “Creating A Simple Authentication Run
As Account” section of Dell Server Management Pack Suite Version 6.3 for Microsoft System Center Operations Manager
User's Guide at dell.com/OMConnectionsEnterpriseSystemsManagement.
NOTE: Add the Server Management Action account to the OpsMgr administrator group.
3. Associate the created Run As Accounts with the Dell CMC Login Account profile and select the appropriate class, group, or
object on which you can configure the profile.
• To enable slot summary discovery for CMC, override the enable property to True in Dell CMC Slot Discovery. It is disabled
by default.
NOTE: After the slot discovery, if you remove the link between Run As Account with Run As Profile, or disable the
slot-discovery workflow, the discovered slots remain with old data.
Feature Management tasks
The following table lists the Chassis monitoring tasks available on the Feature Management Dashboard. Some tasks listed in the
Feature Management tasks table appear only after you have imported the Chassis monitoring feature.
NOTE: In the Event log, ignore the errors pertaining to reimporting of existing management packs under the error logs.
These errors occur when Feature Management Dashboard reimports all the dependent management packs that are
already imported while importing a monitoring feature.
NOTE: Wait for a task to complete (view the state update change in the dashboard) before launching another task using
the Feature Management Dashboard.
28