Install Guide
7
Chassis Monitoring Feature
The Chassis monitoring feature supports discovery and monitoring of Chassis Management Controller (CMC) on Dell PowerEdge
FX2/FX2s chassis, Dell PowerEdge VRTX chassis, Dell PowerEdge M1000e chassis, and Dell OEM Ready chassis using SNMP or
WS-MAN protocol.
Chassis monitoring feature also supports Detailed monitoring of individual chassis components in the supported OpsMgr.
Management Packs
After the Dell Server Management Pack Suite management packs are successfully imported, the following management packs
should appear in the Administration pane of the OpsMgr console. For more information, see Importing the Dell Server Management
Packs into OpsMgr.
The following table lists the required management packs for the chassis monitoring feature.
Table 15. Required Management Packs
Feature Default Location of Management
Packs
Required Management Packs
Chassis Monitoring
Library
C:\Program Files\Dell Management
Packs\Server Mgmt Suite
\6.3\Library
Scalable and Detailed
Management Packs
C:\Program Files\Dell Management
Packs\Server Mgmt Suite
\6.3\Chassis Monitoring
Library
• Dell.Connections.HardwareLibrary.mp
• Dell.OperationsLibrary.Common.mp
Scalable Feature
• Dell.CMC.OM07.mp — OpsMgr 2007 R2
• Dell.CMC.OM12.mp — OpsMgr 2012
• Dell.Model.Server.mp
• Dell.OperationsLibrary.CMC.mp
• Dell.View.CMC.mp
Detailed Feature
• Dell.Chassis.Detailed.mp and all scalable
management packs.
Configuration prerequisites
• Ensure that SNMP ports on firewall are enabled.
• Ensure that Dell Device Helper is installed.
• Ensure that there is WS-MAN (WS-Management) connectivity between the Management Server and the Managed Node.
Chassis Monitoring requirements
• For slot discovery and correlation to work; ensure that you have Dell Device Helper utility installed.