Release Notes

Issue (310069):
After you remove the management pack, the management pack folders still show up in SCOM console.
Resolution
Close and re-open the SCOM console.
Versions Affected
All.
Issue (406763):
When the network cable is pulled out, iDRAC object may not accurately reflect the state of the iDRAC
network interface for modular blade.
Resolution
None.
Versions Affected
Server Monitoring (Agent-based) 6.x
iDRAC Modular Firmware - all versions
Issue (420180):
After server reboot, it may be possible for the network interface ordering to change, and hence may be
mapped to a different network interface name. Performance statistics are collected based on the
network interface name, and hence may start collecting for a different network interface.
Resolution
None.
Versions Affected
Server Monitoring (Agent-based) 6.x
Issue (323381):
With certain firmware versions of the iDRAC6 monolithic device, the firmware version attribute may
have a value with a trailing "\n".
Resolution
None.
Versions Affected
DRAC Monitoring 6.x
iDRAC6 Monolithic Firmware
Issue (433503):