Users Guide

NOTE: Select the Run As accounts created for discovering the chassis devices. For more
information, see the "Configuring Dell Chassis Management Controller feature for correlating
Server modules with Chassis slot summary" section of the Dell Server Management Pack Suite
Version 6.1 for Microsoft System Center Operations Manager Installation Guide at dell.com/
OMConnectionsEnterpriseSystemsManagement.
5. On the Add a Device console screen in OpsMgr 2012, type the IP address that you want to scan,
select the appropriate Run As account from the SNMP V1 or V2 Run As account drop-down box.
6. Enable the Chassis monitoring feature using the Feature Management Dashboard.
Discoveries by the Dell Chassis Monitoring Feature
Table 21. Dell Chassis Monitoring Feature Discoveries
Discovery Object Description
Dell CMC Discovery Discovers all supported Dell CMCs, Dell
PowerEdge FX2, Dell PowerEdge VRTX, and Dell
PowerEdge M1000e.
Dell CMC Slot Discovery Discovers slots on the CMC device.
Dell Chassis Detailed Discovery Discovers all Dell chassis components.
Monitoring
After you install the Dell Server Management Pack Suite, you can use the Monitoring pane of the OpsMgr
to select views that provide complete health information of the discovered Dell CMC devices. The
Chassis monitoring feature discovers and monitors the health of the Dell CMC devices. The Severity Level
Indicators indicates the health of the Dell CMC devices on the network.
Chassis Monitoring includes monitoring the health of Dell chassis devices, both at regular intervals and on
occurrence of events.
NOTE: To perform Chassis Detailed monitoring, create Run As Accounts with WS-Man credentials
needed for accessing the Dell CMCs and associate it to the profiles — Dell CMC Login Account Run
As Profiles.
Monitored hardware components
The following table provides information on the monitored hardware components supported in Scalable
and Detailed feature.
Table 22. Monitored hardware components — Scalable and Detailed feature
Hardware Components Scalable Detailed
CMC Slot Information
No No
CMC Slot
No No
Fan Group
No Yes
58