Users Guide
Example
When you run the Clear ESM Logs task, on the task execution screen only the result of the task initiating is displayed. For
example, the task execution screen may show a success result even if the ESM logs are not cleared. This means that the Clear
ESM Logs task initiation was successful.
Launch Dell OpenManage Server Administrator
About this task
To launch Server Administrator:
Steps
1. In the OpsMgr console, navigate to a Dell Diagram Views, State Views, or Alerts Views.
2. Select the desired Dell server in any of the Diagram Views or State Views or an alert in the Alerts Views.
3. In the Tasks pane, select Dell Windows Server Tasks > Launch Server Administrator.
NOTE: The Dell Server Management Pack Suite tasks launch the remote console in the Internet Explorer.
Launch Remote Desktop
About this task
To launch remote desktop:
Steps
1. In the OpsMgr console, navigate to a Dell Diagram Views, State Views, or Alerts Views.
2. Select the desired Dell server in any of the Diagram Views or State Views or an alert in the Alerts Views.
3. In the Tasks pane, select Dell Windows Server Tasks > Launch Remote Desktop.
NOTE: Launching remote desktop is possible only if the remote desktop is enabled manually in the managed node.
Launch Dell Remote Access Console
About this task
To launch Dell Remote Access console:
Steps
1. In the OpsMgr console, navigate to a Dell Diagram Views, State Views, or Alerts Views.
2. Select the desired Dell server in any of the Diagram Views or State Views or an alert in the Alerts Views.
3. In the Tasks pane, select Dell Windows Server Tasks > Launch Dell Remote Access Console.
Check Power Status
About this task
You can check the power status and allow power control tasks through the IPMI shell.
NOTE:
To enable Advanced Power Control, install Baseboard Management Controller Management Utility (BMU) in the
default path. If BMU is not installed in the default path, create a new console task. For more information on creating a new
console task, see Creating Advanced Power Control And LED Identification Tasks.
To check the power status of a system:
24