Setup Guide
For example, to upgrade Chassis Monitoring feature, click Upgrade Chassis Monitoring Feature under Dell Monitoring
Feature Tasks.
6. On the Run Task — Upgrade Monitoring Feature screen, click Override.
Override Task Parameters are displayed.
7. From the drop-down menu in the New Value column, change the value of AutoResolve Warnings/Errors to True.
8. Click Override.
9. Click Run to run the task.
Feature Management alerts
Table 21. Feature Management alerts
Alert Text Alert State Cause Resolution
Dell FMP: Dell Device
Helper Utility is either not
present or incompatible
with Dell Agent-free
monitoring Management
Pack.
Critical
The required Dell Device Helper
Utility version was not found or
the Dell Device Helper Utility is
corrupted.
A version higher than the
required Dell Device Helper
Utility version was found.
A version lower than the
required Dell Device Helper
Utility version was found.
Run the Dell Server
Management Pack Suite
version 6.1.1 installer on the
management server.
Health Service of the Feature Management Host
Server is nonfunctional
In a distributed setup, the management server where the Dell Server Management Pack suite is installed first is selected to host
all feature management activities such as discoveries, alerts and tasks. If the selected management server has stopped
functioning, the executed Feature Management task fails, and Feature Management Dashboard is not populated. If such a
selected management server is corrupt or health service is not obtained, decommission the management server to remove stale
objects. For more information, see technet.microsoft.com/en-us/library/hh456439.aspx.
To populate the Feature Management Dashboard:
1. In the OpsMgr console, click Authoring.
2. In Authoring, expand Management Pack Objects.
3. Click Object Discoveries.
4. In the Look for: field, search Dell Feature Management Host Discovery.
5. Right-click Dell Feature Management Host Discovery and select Overrides > Override the Object Discovery > For all
objects of class: Dell Feature Management Host Discovery.
6. Select FmpHostFqdn and set the override value to FQDN of the management server where the feature management
activities have to run.
32
Troubleshooting