Setup Guide

Chassis Monitoring Feature
Chassis monitoring feature supports discovery and monitoring of Chassis Management Controller (CMC) on Dell PowerEdge
FX2/ FX2s chassis, Dell PowerEdge VRTX chassis, and Dell PowerEdge M1000e chassis using SNMP and WS-Man.
Chassis monitoring feature also supports Detailed monitoring of individual chassis components in OpsMgr 2012.
Topics:
Management Packs
Management Server (MS) requirements
Feature Management tasks
Management Packs
After the Dell Server Management Pack Suite management packs are successfully imported, the following management packs
should appear in the Administration pane of the OpsMgr console. For more information, see Importing the Dell Server
Management Packs into OpsMgr.
The following table lists the required management packs for the chassis monitoring feature.
Table 16. Required Management Packs
Feature Default Location of
Management Packs
Required Management Packs
Chassis Monitoring
Library
C:\Program Files\Dell
Management Packs\Server
Mgmt Suite\6.1.1\Library
Scalable and Detailed
Management Packs
C:\Program Files\Dell
Management Packs\Server
Mgmt Suite\6.1.1\Chassis
Monitoring
Library
Dell.Connections.HardwareLibrary.mp
Dell.OperationsLibrary.Common.mp
Scalable Feature
Dell.CMC.OM07.mp OpsMgr 2007 R2
Dell.CMC.OM12.mp OpsMgr 2012
Dell.Model.Server.mp
Dell.OperationsLibrary.CMC.mp
Dell.View.CMC.mp
Detailed Feature
Dell.Chassis.Detailed.mp and all scalable
management packs.
Management Server (MS) requirements
Software requirements
Table 17. Software requirements
Software Purpose
DRAC tools from Dell OpenManage Server Administrator
To discover Chassis and Chassis Slot Summary and Server
Modules for CMC Chassis
Chassis Detailed Monitoring
7
26 Chassis Monitoring Feature