Release Notes
• The "Dell CMC Slot Discovery" uses racadm to connect to CMC devices. Racadm uses Internet
Explorer Proxy Settings of SCOM Health Service user account to connect to the CMC devices.
Ensure that Internet Explorer Proxy Settings of the SCOM Health Service user account is
configured such that CMC devices are reachable. For instructions on modifying the Internet
Explorer settings, see Microsoft KB article 135982.
• To monitor the health of Chassis devices, associate the community string Run As account with
the SNMP Monitoring Account with the target as Dell Modular Chassis class or respective Chassis
object (if you have different Run As accounts for different Chassis devices).
Known Issues
Issue (368):
Memory of type DDR4 is reported by Server Monitoring (Agent-based) as "Unknown".
Resolution
None.
Versions Affected
• Server Monitoring (Agent-based) 6.x
• OpenManage Server Administrator 8.x.x
Issue (546218):
If Dell OpenManage Power Center is installed on a port other than the default port 8463, the associated
Console Task fails.
Resolution
Install the Dell OpenManage Power Center on default port on the management server.
Versions Affected
Server Monitoring (Agent-based) 6.x
Issue (307678):
Dell Server "Operating System" attribute may not show the trademark and registered symbols properly.
Resolution
None.
Versions Affected
Server Monitoring (Agent-based) 6.x
Issue (310069):
After you remove the management pack, the management pack folders still show up in SCOM console.