Each of these rules are processed based on the following criteria:
Source Name = "DRAC/CMC/DRAC/MC name or ip"
OID = Actual trap ID of the DRAC /CMC/DRAC/MC SNMP trap event
Data Provider = SNMP trap
NOTE: Informational alerts are turned off by default. Import informational alerts on MP to get these.
Dell Servers
All informational, warning, and critical SNMP traps for Dell servers discovered using Server (Out-of-band) Monitoring
feature, have a corresponding SNMP trap rule.
Each of these rules are processed based on the following criteria:
Source Name = "Dell Server ip"
OID = Actual trap ID of the trap event
Data Provider = SNMP trap event provider
Performance Collection Rules
In the OpsMgr console, click Monitoring DellPerformance and Power Monitoring Views to view the performance
information that is collected from Dell servers. By default this feature is disabled, to enable the feature, see
Enabling
Performance Collection Rules.
The performance collection rules collects information on the following parameters:
Ambient Temperature (Centigrade)
Amperage (Amps)
Dell Performance View
Energy Consumption (kWh)
Peak Amperage (Amps)
Peak Power (Watts)
Physical Network Interface
Power Consumption (BTU/hr)
Power Consumption (Watts)
Teamed Network Interface
NOTE: When the Detailed edition of Server Management Feature is imported, the disabled Performance (excluding
Network Performance) collection rules are enabled by default.
NOTE: Network Statistics are defined in Detailed edition of Server Monitoring Feature only and are disabled by
default. To enable the feature, see Enabling Performance Collection Rules.
Enabling Performance Collection Rules
To enable this feature:
1. Launch OpsMgr console and click Authoring.
2. Click Rules and search for performance collection rules.
3. Right-click the rule you want to enable.
For example, to collect information on Network Interface of all Dell systems, perform step 4 to step 5 for the rules
listed below:
38