With certain firmware versions of the iDRAC6 monolithic device, the firmware version attribute may have
a value with a trailing "\n".
Resolution
None
Versions Affected
DRAC Monitoring 5.0.1, iDRAC6 Monolithic Firmware
Issue (DF431523)
You cannot discover slots for DRAC/MC devices with firmware version 1.6 with an Active Directory (AD)
account. Alternatively, you can discover the slots with Local User Accounts.
Resolution
None
Versions Affected
Chassis Monitoring 5.0.1, DRAC/MC Firmware 1.6
Issue (DF433503)
Temporary files are not removed when racadm tool fails. When remote racadm takes a long time to get
server module/free slot information from CMC or DRAC/MC device, SCOM may terminate the "CMC Slot
Discovery" and "DRAC/MC Slot Discovery" scripts. As a result, you will see "Script or Executable failed to
Run" alert in the SCOM Alerts View and some files will be left over in
the %windir%\Temp\ChassisRemoteAccess_Logs directory on the management station managing the CMC or
DRAC/MC device. You can ignore the alert and manually remove the temporary files.
Resolution
Remove the temporary files manually.
Versions Affected
Chassis Monitoring 5.0.1
Issue (DF554331)
On SCOM 2007 R2 distributed setups, though a FMP task is completed functionally and Task History too
shows this as complete, on occasions SCOM may still continue to have task popup in running state.
Resolution
Close the task popup window.
Versions Affected
Feature Management (5.0.1), SCOM 2007 R2 (Distributed Environment)
Issue (DF545775)
After the user updates the default port number, CMC/DRAC firmware with version 3.0 returns wrong URL.