Owner's Manual

To use the Out-of-Band features, download the Microsoft WS-Management template from the
Microsoft download location mentioned in the Dell Server Management Pack Suite Version 5.0.1
User’s Guide.
Performance rules are disabled by default. Enable "Dell Server Performance rule" to view the
Server performance data (temperature, power and Network Interface Card (NIC)).
Remote Access Monitoring:
The Unit Monitor "Device Status Check" is disabled for all Dell Remote Access Controllers in the
Dell Remote Access Controller Management Pack for SCOM 2007 R2/SCE 2010.
Chassis Monitoring:
The Discovery Rule "Dell CMC Slot Discovery" is disabled for all Dell Chassis Management
Controllers in the Dell Chassis Management Controller Management Pack. Enable this rule to
discover server modules and free slots for Dell Chassis Management Controllers after you have
created Run As Accounts for the CMC devices in your network and associated them with the "Dell
CMC Login Account". For more information on configuring Run As Accounts refer to the User’s
Guide.
The Discovery Rule "Dell DRAC/MC Slot Discovery" is disabled for all Dell Modular Chassis Remote
Access Controllers in the Dell Chassis Management Controller Management Pack. Enable this rule
to discover server modules and free slots for Dell Modular Chassis Remote Access Controllers after
you have created Run As Accounts for the DRAC/MC devices in your network and associated them
with the "Dell DRAC/MC Login Account". For more information on configuring Run As Accounts
refer to the User’s Guide.
The Unit Monitor "Device Status Check" is disabled for all Dell Chassis Management Controllers and
Dell Modular Chassis Remote Access Controllers in the Dell Chassis Management Controller
Management Pack for SCOM 2007 R2/SCE 2010.
The "Dell CMC Slot Discovery" and "Dell DRAC/MC Slot Discovery" uses racadm to connect to CMC
and DRAC/MC devices. The racadm uses Internet Explorer Proxy Settings of SCOM Health Service
user account to connect to the CMC and DRAC/MC Devices. Ensure that Internet Explorer Proxy
Settings of the SCOM Health Service user account is configured such that CMC and DRAC/MC
devices are reachable. For instructions on modifying the Internet Explorer settings, see Microsoft
KB article 135982.
Open Issues and Resolutions
Fixed Issu es/def
Issue (DF546218)
If Dell OpenManage Power Center is installed on a port other than the default port 8463, the associated
Console Task to launch it will fail.
Resolution
Install Dell OpenManage Power Center on default port on the management server.