Owner's Manual
• Data Provider = Windows system event log
DRAC, CMC, Or DRAC/MC
All informational, warning, and critical SNMP traps for the DRAC, CMC, and DRAC/MC devices have a corresponding
SNMP trap rule.
Each of these rules are processed based on the following criteria:
• Source Name = "DRAC/CMC/DRAC/MC name or ip"
• OID = Actual trap ID of the DRAC /CMC/DRAC/MC SNMP trap event
• Severity = Severity of the actual event
• Data Provider = SNMP trap
Dell Servers
All informational, warning, and critical SNMP traps for Dell Servers discovered using Server (Out-of-band) Monitoring
feature, have a corresponding SNMP trap rule.
Each of these rules are processed based on the following criteria:
• Source Name = "Dell Server ip"
• OID = Actual trap ID of the trap event
• Data Provider = SNMP trap event provider
Performance Collection Rules
In the OpsMgr console, click Monitoring → Dell → Performance and Power Monitoring Views to view the performance
information that is collected from Dell systems. By default this feature is disabled, to enable the feature, see Enabling
Performance Collection Rules.
The performance collection rules collect information on the following parameters:
• Ambient Temperature (Centigrade)
• Amperage (Amps)
• Energy Consumption (kWh)
• Peak Amperage (Amps)
• Peak Power (Watts)
• Physical Network Interface
• Power Consumption (Watts)
• Power Consumption (BTU/hr)
• Teamed Network Interface
• Dell Performance View
Enabling Performance Collection Rules
To enable this feature:
1. Launch OpsMgr console and click Authoring.
2. Select Rules.
3. Right-click the rule you want to enable.
34