Install Guide
Description: Systems with software RAID show incorrect number of hard drives on the storage overview page.
Version affected: All
Resolution/Workaround: None. The ESXi does not support software RAID. If the system has software RAID, it shows incorrect disks.
• Issue 7: System Event Logs are not showing in OpenManage Integration for VMware vCenter when power supply redundancy is lost.
Description: When the power redundancy is lost on the PowerEdge modular servers, the system logs get cleared.
Version affected: 3.0 and later
Resolution/Workaround: None
• Issue 8: Chassis and server health is displayed as warning on the Chassis Summary page when server becomes critical.
Description: When a critical entry is made to SEL logs, the health of the server (modular) changes to critical. This is correctly reflected
on the Host Summary page. However, this is not reflected on the Chassis Summary page. The server health is displayed as warning. If
the chassis was normal earlier, the health of the chassis also changes to warning.
Version affected: 3.0 and later
Resolution/Workaround: None. This is a known defect in the RACADM. The defect will be fixed in the next release of RACADM for
chassis.
• Issue 9: The hard drive name is not displayed at data center and cluster level inventory in some situations.
Description: Although the hard drive name is displayed when you view the inventory at the host level, the hard drive name is displayed
empty when you view the inventory of the host at the data center and cluster level.
Version affected: 3.0 and later
Resolution/Workaround: This issue does not affect the functionality of the features, and you can view the inventory at the host level
to see the hard drive name.
• Issue 10: Hard disk option is not disabled in the Deployment wizard for all the servers that do not contain hard disk drives.
Description: While navigating through the Deployment wizard, if the bare-metal servers do not have any hard disk drive, and then the
hard disk option should be disabled on the Select Deployment Options page. However, the option is available for selection.
Version affected: 2.0 and later
Resolution/Workaround: None
• Issue 11: Using OpenManage Integration to update an Intel Network card with the firmware version of 13.5.2 is not supported.
Description: There is a known issue with Dell EMC PowerEdge 12th generation servers and some Intel network cards with the
firmware version of 13.5.2. Updating some models of the Intel network cards at this version of firmware fails when the firmware
update is applied using the iDRAC with Lifecycle Controller.
Version affected: All
Resolution/Workaround: Update the network driver software using an operating system. If the Intel network card has a version of
firmware other than 13.5.2, you can update using OpenManage Integration.
NOTE:
When using the one-to-many firmware update, avoid selecting Intel network adapters that are at version 13.5.2, as
this fails and stops the update task from updating remaining servers.
• Issue 12: Firmware upgrade or downgrade of Broadcom NetXtreme II 10-Gigabit Ethernet adapter (BCM57712) from firmware version
of 6.2.x or earlier is not supported.
Description: Using the OpenManage Integration to upgrade a Broadcom NetXtreme II 10-Gigabit Ethernet adapter (BCM57712) from
firmware version of 6.2.x or earlier, or downgrade to a firmware version of 6.2.x or earlier is not supported.
Version affected: All
Resolution/Workaround: There is a known issue with the Broadcom NetXtreme II 10-Gigabit Ethernet adapter (BCM57712) where
updating the adapter from firmware version of 6.2.x or earlier, or downgrade to a firmware version of 6.2.x or earlier fails when the
update is applied using the iDRAC with Lifecycle Controller.
When attempting to perform this update using the OpenManage Integration, the update may incorrectly show that it completed
successfully. However, the firmware update has failed and remains at the previous level. One way to successfully update the adapter
software for the Broadcom NetXtreme II 10-Gigabit Ethernet adapter (BCM57712) is to update the adapter firmware from an
operating system.
• Issue 13: Associated host credential profile is not displayed on the management compliance page when inventory is not able to get
iDRAC IP for the host.
Description: If the iDRAC IP is not retrieved because of non-responsive iDRAC, the inventory fails and host to be associated with the
host credential profile is not displayed on the management compliance page.
10
Known issues