User's Manual
76 Events and Messages
0x00d1 Info BBU Retention test was initiated on previous boot
0x00d2 Info BBU Retention test passed
0x00d3 Caution BBU Retention test failed!
0x00d4 Info NVRAM Retention test was initiated on previous boot
0x00d5 Info NVRAM Retention test passed
0x00d6 Caution NVRAM Retention test failed!
0x00d7 Info %s test completed %d passes successfully
0x00d8 Caution %s test FAILED on %d pass. Fail data: errorOffset=%x
goodData=%x badData=%x
0x00d9 Info Self check diagnostics completed
0x00da Info Foreign Configuration Detected
0x00db Info Foreign Configuration Imported
0x00dc Info Foreign Configuration Cleared
0x00dd Warning NVRAM is corrupt; reinitializing
0x00de Warning NVRAM mismatch occurred
0x00df Warning SAS wide port %d lost link on PHY %d
0x00e0 Info SAS wide port %d restored link on PHY %d
0x00e1 Warning SAS port %d, PHY %d has exceeded the allowed error rate
0x00e2 Warning Bad block reassigned on %s at %lx to %lx
0x00e3 Info Controller Hot Plug detected
0x00e4 Warning Enclosure %s temperature sensor %d differential detected
0x00e5 Info Disk test cannot start. No qualifying disks found
0x00e6 Info Time duration provided by host is not sufficient for self
check
0x00e7 Info Marked Missing for %s on array %d row %d
0x00e8 Info Replaced Missing as %s on array %d row %d
0x00e9 Info Enclosure %s Temperature %d returned to normal
Table A-2. Event Messages (continued)
Number Type Event Text