User's Manual

Troubleshooting 61
Other Dell SAS RAID Storage Manager Messages
Table 7-2 lists other messages generated by Dell SAS RAID Storage Manager
and explains what should be done to respond to them.
Table 7-2. Dell SAS RAID Storage Manager Messages
Message Meaning Action
Event ID 0X27 This means that patrol read
is disabled. This message
displays if you try to start
patrol read when it is not
enabled.
Change the patrol read mode to
Auto or Manual from Disabled. See
Running a Patrol Read
in Chapter 5
for detailed instructio ns.
Message 4007 A Start Rebuild command
was issued, but rebuild was
not able to start.
See the Dell knowledgebase articles
on
support.dell.com
.
Message 4008 A Make Drive Online
command was issued.
See the Dell knowledgebase articles
on
support.dell.com
.
Message 4009 You are attempting to create
a virtual disk with a mix of
SAS and SATA physical
drives.
The operation is not supported.
Select only SAS or only SATA drives
when creating a virtual disk.
Message 4022 Required hardware, such as
a battery backup unit, is
missing.
No action is required; these
functions are not supported.
Message 8107 You sent a Start Locate or
Stop Locate command to a
physical drive that is not
connected to a backplane
(that is, not in a disk
enclosure).
Command not supported on this
hardware config (informational
message only).
Message 8109 File selected to upgrade
firmware is invalid for that
controller.
See
Upgrading the Firmware
for
instructions on how to upgrade the
firmware.
Message 800E You sent an Undo Prepare
Removal command to a
physical drive that does not
support this command.
The hardware configuration is not
supported.