Release Notes
● After the iSCSI installation, during boot, add the following boot parameter:
rd.net.timeout.carrier=7
Systems
affected:
All Dell EMC PowerEdge servers
Tracking number: 124792
RHEL 8 installation fails on systems with Emulex
OneConnect card
Description: When RHEL 8 is installed on an iSCSI LUN that is configured on Emulex OneConnect card on Dell EMC
13G systems, the installation fails with a UnicodeDecodeError. This error occurs because the
Anaconda installer is unable to decode the iSCSI initiator name.
Applies to: RHEL 8.0
Workaround: There is no workaround available for this issue, but the LUN can be used as DATA LUN.
Systems
affected:
All Dell EMC 13G systems
Tracking number: 111760
Switching between runlevels fails
Description:
Switching from runlevel 5 to 3 fails.
Applies to: RHEL 8.0
Workaround: Switch to different TTYs (Ctrl+Alt+F2/F3) to continue using the system.
Systems
affected:
All Dell EMC PowerEdge servers
Tracking number: 124039
24 Known issues