Release Notes
Known issues
Topics:
• Caps Lock key-press is not registered on the Dell PowerEdge iDRAC virtual console
•
RHEL 8.3 installer does not automatically locate the source installation repository when only inst.stage2=hd boot option is
used
• The mdmonitor service displays an error during operating system installation
• The output of the systemctl status command displays the status as thawing
• The dmidecode utility displays the slot type as <OUT OF SPEC> for PCIe Gen 4 NVMe slots
• Advanced Configuration and Power Interface (ACPI) error messages displayed in dmesg
• Drivers available in OEMDRV drive are not installed during the operating system installation
• The Mellanox IB devices are listed under an incorrect device category on Red Hat Enterprise Linux 8
• The lspci utility is unable to read Vital Product Data (VPD) from QLogic QLE2692 adapter
• Driver dependency mismatch errors reported while installing out-of-box drivers on Red Hat Enterprise Linux 8.x
• Dmesg displays TPM and nvdimm related-messages in Red Hat Enterprise Linux 8.1
• Link Up message is observed when the NVMe device slot is powered off and the device is unplugged
• Mellanox InfiniBand adapters are listed in Bluetooth
• iscsiadm output displays STATIC in the iface.bootproto field when the network interface is configured to DHCP
• When system reboots, system stops responding at the end of the reboot process
• Unable to shut down RHEL 8 when you select Graceful shutdown option or when you press power button on the server
• RHEL 8 does not discover FCoE LUNs connected over Broadcom BCM57XXX NICs
• iSCSI LUN not discovered during RHEL 8 installation
• RHEL 8 installation fails on systems with Emulex OneConnect card
• Switching between runlevels fails
Caps Lock key-press is not registered on the Dell
PowerEdge iDRAC virtual console
Description:
The Caps Lock key-press is not registered when the Dell PowerEdge iDRAC virtual console is used. The
console displays lowercase letters when the Caps Lock key is enabled.
Applies to: Red Hat Enterprise Linux 8.0, Red Hat Enterprise Linux 8.1 , Red Hat Enterprise Linux 8.2
Workaround: Do the following:
1. Create the file /etc/udev/rules.d/99-kbd.rules and add the rule:
ACTION=="add", SUBSYSTEM=="leds", ENV{DEVPATH}=="*/input*::capslock",
ATTR{trigger}="kbd-ctrlllock"
2. Run the command: udevadm control --reload-rules
3. Disconnect and reconnect the Dell PowerEdge iDRAC virtual console.
Systems
affected:
All Dell EMC PowerEdge servers
Tracking number: 176749
6