Release Notes

Known issues
Topics:
Caps Lock key-press is not registered on the Dell PowerEdge iDRAC virtual console
RHEL 8.3 installer does not automatically locate the source installation repository when only inst.stage2=hd boot option is
used
The mdmonitor service displays an error during operating system installation
The output of the systemctl status command displays the status as thawing
The dmidecode utility displays the slot type as <OUT OF SPEC> for PCIe Gen 4 NVMe slots
Advanced Configuration and Power Interface (ACPI) error messages displayed in dmesg
Drivers available in OEMDRV drive are not installed during the operating system installation
The Mellanox IB devices are listed under an incorrect device category on Red Hat Enterprise Linux 8
The lspci utility is unable to read Vital Product Data (VPD) from QLogic QLE2692 adapter
Driver dependency mismatch errors reported while installing out-of-box drivers on Red Hat Enterprise Linux 8.x
Dmesg displays TPM and nvdimm related-messages in Red Hat Enterprise Linux 8.1
Link Up message is observed when the NVMe device slot is powered off and the device is unplugged
Mellanox InfiniBand adapters are listed in Bluetooth
iscsiadm output displays STATIC in the iface.bootproto field when the network interface is configured to DHCP
When system reboots, system stops responding at the end of the reboot process
Unable to shut down RHEL 8 when you select Graceful shutdown option or when you press power button on the server
RHEL 8 does not discover FCoE LUNs connected over Broadcom BCM57XXX NICs
iSCSI LUN not discovered during RHEL 8 installation
RHEL 8 installation fails on systems with Emulex OneConnect card
Switching between runlevels fails
Caps Lock key-press is not registered on the Dell
PowerEdge iDRAC virtual console
Description:
The Caps Lock key-press is not registered when the Dell PowerEdge iDRAC virtual console is used. The
console displays lowercase letters when the Caps Lock key is enabled.
Applies to: Red Hat Enterprise Linux 8.0, Red Hat Enterprise Linux 8.1 , Red Hat Enterprise Linux 8.2
Workaround: Do the following:
1. Create the file /etc/udev/rules.d/99-kbd.rules and add the rule:
ACTION=="add", SUBSYSTEM=="leds", ENV{DEVPATH}=="*/input*::capslock",
ATTR{trigger}="kbd-ctrlllock"
2. Run the command: udevadm control --reload-rules
3. Disconnect and reconnect the Dell PowerEdge iDRAC virtual console.
Systems
affected:
All Dell EMC PowerEdge servers
Tracking number: 176749
6