- Fixes
- BIOS update does not complete when an update is performed using the Linux .BIN files
- Dmesg shows drm related call trace in RHEL 8.3
- Operating system crashes on servers with NVIDIA GPGPUs
- Dmesg and /var/log/messages display AMD-Vi related messages
- The status of the NetworkManager service may be inactive when RHEL 8.3 is rebooted
- Operating system crashes on AMD Rome CPU-based systems and with Intel E810 NIC
- The lvcreate command requests a response from the user when -wipesignature -yes parameters are passed
- The mdmonitor service displays an error during operating system installation
- The dmidecode utility displays the slot type as
for PCIe Gen 4 NVMe slots - The mcelog utility logs 'only decoding architectural errors' message in var/log/messages
- Disk drives part of MD RAID are not listed as installation destination by the installer
- Dell EMC OpenManage Storage Services utility fails to reconfigure the virtual disk
- Guest VMs with SRIOV VFs assigned take a long time to power on, and libvirt related errors are observed
- Dmesg displays Integrity Measurement Architecture (IMA) driver related-messages during system boot
- After every reboot, the network interface name changes
- Red Hat Enterprise Linux Version 8 installation wizard creates a duplicate bonding interface
- Servers with the AMD Rome processor display a CCP initialization failure message in dmesg
- PowerEdge servers with the AMD Rome processor fail to detect an NVMe drive after multiple hot plugs
- Operating system enters the dracut shell during boot
- System crashes when rebooted with SR-IOV-enabled QLogic cards
- After system reboot, Disk data format (DDF) devices are not listed in /proc/mdstat
- Updating NVMe firmware using the nvme-cli utility displays an error in dmesg
- Fatal error BDF 02:00.0 is detected with BCM574xx NICs
- NVMe devices are not detected after hot-plugging
- Linux operating system fails to detect the Intel x710 card
- Dmidecode displays OUT OF SPEC in Slot Type and Slot Length of SMBIOS system slots
- Custom partitioning fails with FC LUN
- When booting the system from iSCSI with Mellanox CX-4 and CX-5 adapters, the system reports csum failure message
- Red Hat Enterprise Linux 8 kernel panic is observed due to fatal hardware error
- Known issues
- System hangs when Intel tboot is used to boot the operating system
- The anaconda installer crashes while autoconfiguring disk partitions
- The version field in the output of the modinfo command for certain networking drivers is null
- NetworkManager may restart unexpectedly when creating greater than 256 VLAN devices configured with DHCP IP
- FCoE session is not reestablished after MX9116N switch is rebooted
- Dmesg displays error messages when NVMe device is surprise removed
- Status of the RAID 0 logical volume is displayed as Available when one of the members of the RAID array is surprise removed
- /proc/mdstat and mdadm -D commands display incorrect statuses when two NVMe devices are surprise removed from a RAID 5 MD array
- Dell Controlled Turbo feature is not functional
- Caps Lock key-press is not registered on the Dell PowerEdge iDRAC virtual console
- RHEL 8.3 installer does not automatically locate the source installation repository when only inst.stage2=hd boot option is used
- The output of the systemctl status command displays the status as thawing
- Advanced Configuration and Power Interface (ACPI) error messages displayed in dmesg
- Drivers available in OEMDRV drive are not installed during the operating system installation
- The Mellanox IB devices are listed under an incorrect device category on Red Hat Enterprise Linux 8
- The lspci utility is unable to read Vital Product Data (VPD) from QLogic QLE2692 adapter
- Driver dependency mismatch errors reported while installing out-of-box drivers on Red Hat Enterprise Linux 8.x
- Dmesg displays TPM and nvdimm related-messages in Red Hat Enterprise Linux 8.1
- Link Up message is observed when the NVMe device slot is powered off and the device is unplugged
- Mellanox InfiniBand adapters are listed in Bluetooth
- iscsiadm output displays STATIC in the iface.bootproto field when the network interface is configured to DHCP
- When system reboots, system stops responding at the end of the reboot process
- Unable to shut down RHEL 8 when you select Graceful shutdown option or when you press power button on the server
- RHEL 8 does not discover FCoE LUNs connected over Broadcom BCM57XXX NICs
- iSCSI LUN not discovered during RHEL 8 installation
- RHEL 8 installation fails on systems with Emulex OneConnect card
- Switching between runlevels fails
- Limitations
- Resources and support
- Contacting Dell EMC
Tracking number: 182820
Dell Controlled Turbo feature is not functional
Description: Dell Controlled Turbo is not functional when the system profile setting in BIOS is set to performance or
custom.
Applies to: Red Hat Enterprise Linux 8.0 and later
Cause: The intel_pstate driver may interfere with the processor settings which results in Dell Controlled Turbo
feature being not functional.
Solution: Prevent the intel_pstate driver from loading. For more information on how to prevent the module from
loading, see Red Hat Enterprise Linux Knowledge Base article 41278.
Tracking number: 167802
Caps Lock key-press is not registered on the Dell
PowerEdge iDRAC virtual console
Description: The Caps Lock key-press is not registered when the Dell PowerEdge iDRAC virtual console is used. The
console displays lowercase letters when the Caps Lock key is enabled.
Applies to: Red Hat Enterprise Linux 8.0, Red Hat Enterprise Linux 8.1 , Red Hat Enterprise Linux 8.2
Workaround: Do the following:
1. Create the file /etc/udev/rules.d/99-kbd.rules and add the rule:
ACTION=="add", SUBSYSTEM=="leds", ENV{DEVPATH}=="*/input*::capslock",
ATTR{trigger}="kbd-ctrlllock"
2. Run the command: udevadm control --reload-rules
3. Disconnect and reconnect the Dell PowerEdge iDRAC virtual console.
Systems
affected:
All Dell EMC PowerEdge servers
Tracking number: 176749
RHEL 8.3 installer does not automatically locate
the source installation repository when only
inst.stage2=hd boot option is used
Description:
When both stage2 and the installation repository are on the same internal drive or external drive (USB
hard drive), RHEL 8.3 installer does not automatically locate the source installation repository when only
inst.stage2=hd boot option is used.
Applies to: Red Hat Enterprise Linux 8.3
Workaround: Modify the boot option inst.stage2=hd:LABEL=<NAME> to inst.repo=hd:LABEL=<NAME>
Systems
affected:
Dell EMC PowerEdge yx4x and yx5x servers
Tracking number: 182181
Known issues 25