Release Notes

Table Of Contents
适用于: Red Hat Enterprise Linux 8.3
解决方法:
将启动选项 inst.stage2=hd:LABEL=<NAME> 修改为 inst.repo=hd:LABEL=<NAME>
受影响的系统: Dell EMC PowerEdge yx4x yx5x 服务器
跟踪号码: 182181
systemctl 状态命令的输出结果显示状态为解冻
说明:
当重新加载服务时,systemctl status <service name> 命令的输出结果显示的状态为 Active:
active (running) (thawing) 而不是 Active: active (running)。此问题只是显示问题,可以
忽略。
适用于: Red Hat Enterprise Linux 8.3
受影响的系统: Dell EMC PowerEdge yx4x yx5x 服务器
跟踪号码: 178127
dmesg 中显示的高级配置和电源接口 (ACPI) 错误消息
说明: 以下与 ACPI 相关的错误消息显示在 dmesg /var/log/messages 中:
[ 10.265354] ACPI Error: No handler for Region [SYSI] (ffff8f04edb31a20)
[IPMI] (20130517/evregion-162)
[ 10.265359] ACPI Error: Region IPMI (ID=7) has no handler (20130517/
exfldio-305)
[ 10.265368] ACPI Error: Method parse/execution failed [\_SB_.PMI0._GHL]
(Node ffff8f106dea07e0), AE_NOT_EXIST (20130517/psparse-536)
[ 10.265376] ACPI Error: Method parse/execution failed [\_SB_.PMI0._PMC]
(Node ffff8f106dea0720), AE_NOT_EXIST (20130517/psparse-536)
[ 10.265381] ACPI Exception: AE_NOT_EXIST, Evaluating _PMC (20130517/
power_meter-753)
这些错误消息与 acpi_power_meter acpi_ipmi 驱动程序的模块相关性和模块加载顺序有关。
适用于: Red Hat Enterprise Linux 8 或更高版本
解决方案: 这些消息仅供参考,可以忽略。请参阅 Red Hat Enterprise Linux 知识库文章 49225 了解详细信息
跟踪号码: 172165
在安装操作系统的过程中不安装 OEMDRV 驱动器中的驱动
程序
说明: 在安装 Red Hat Enterprise Linux 过程中,操作系统会间歇性地无法在驱动程序磁盘探测阶段枚举 USB 驱动
器。这会阻止安装 LC/OEMDRV 中的驱动程序。
适用于: Red Hat Enterprise Linux 8 或更高版本
解决方法: 使用内核启动参数命令“inst.dd=LABEL=OEMDRV”将驱动程序安装在 OEMDRV 驱动器中。
受影响的系统: Dell EMC PowerEdge 服务器
跟踪号码: 168569
已知问题 25