The mcelog utility logs 'only decoding architectural errors' message in var/log/messages
Disk drives part of MD RAID are not listed as installation destination by the installer
Dell EMC OpenManage Storage Services utility fails to reconfigure the virtual disk
Guest VMs with SRIOV VFs assigned take a long time to power on, and libvirt related errors are observed
Dmesg displays Integrity Measurement Architecture (IMA) driver related-messages during system boot
After every reboot, the network interface name changes
Red Hat Enterprise Linux Version 8 installation wizard creates a duplicate bonding interface
Servers with the AMD Rome processor display a CCP initialization failure message in dmesg
PowerEdge servers with the AMD Rome processor fail to detect an NVMe drive after multiple hot plugs
Operating system enters the dracut shell during boot
System crashes when rebooted with SR-IOV-enabled QLogic cards
After system reboot, Disk data format (DDF) devices are not listed in /proc/mdstat
Updating NVMe firmware using the nvme-cli utility displays an error in dmesg
Fatal error BDF 02:00.0 is detected with BCM574xx NICs
NVMe devices are not detected after hot-plugging
Linux operating system fails to detect the Intel x710 card
Dmidecode displays OUT OF SPEC in Slot Type and Slot Length of SMBIOS system slots
Custom partitioning fails with FC LUN
When booting the system from iSCSI with Mellanox CX-4 and CX-5 adapters, the system reports csum failure message
Red Hat Enterprise Linux 8 kernel panic is observed due to fatal hardware error
The mcelog utility logs 'only decoding architectural
errors' message in var/log/messages
Description:
The mcelog utility logs 'only decoding architectural errors' message in /var/log/messages.
mcelog: Family 6 Model 106 CPU: only decoding architectural errors
mcelog: Family 6 Model 106 CPU: only decoding architectural errors
Applies to:
Red Hat Enterprise Linux 8.2
Solution: This issue is resolved in Red Hat Enterprise Linux 8.3.
For more information, see Red Hat Enterprise Linux Knowledge Base article 6032341.
Systems
affected:
Dell EMC PowerEdge R750, Dell EMC PowerEdge R650, Dell EMC PowerEdge C6525, Dell EMC
PowerEdge MX750C.
Tracking number: 166937
Disk drives part of MD RAID are not listed as
installation destination by the installer
Description:
During installation, if a disk drive which was previously part of MD RAID volume is used, it is not listed as
an installation destination by the operating system installer.
5
Fixes 9