Release Notes

Table Of Contents
The dmidecode utility displays the slot type as <OUT
OF SPEC> for PCIe Gen 4 NVMe slots
Description:
The dmidecode utility displays the Slot Type field of Type 9 record as <OUT OF SPEC> for PCIe
Generation 4 NVMe slots.
Applies to: Red Hat Enterprise Linux 7.6 and later
Cause: The dmidecode utility does not support the Slot Type value of 0x24 that is defined in System
Management BIOS (SMBIOS) version 3.4.
Systems
affected:
Dell EMC PowerEdge R6515, Dell EMC PowerEdge R7515, Dell EMC PowerEdge R6525, Dell EMC
PowerEdge R7525, and Dell EMC PowerEdge C6525.
Tracking number: 171943
Access Vector Cache (AVC) denial messages are
displayed when NVMe disk is hot inserted
Description: The following Access Vector Cache (AVC) denial messages are displayed when NVMe disk is hot inserted:
type=AVC msg=audit(1592925748.673:212): avc: denied
{ read } for pid=9349 comm="smartd" name="nvme0"
dev="devtmpfs" ino=12595 scontext=system_u:system_r:fsdaemon_t:s0
tcontext=system_u:object_r:nvme_device_t:s0 tclass=chr_file permissive=0
Applies to: Red Hat Enterprise Linux 7.5 and later
Cause: SMART Disk Monitoring Daemon tries to monitor the NVMe drives but gets blocked due to enforced
SELinux policies. This issue is related to SMARTD monitoring /dev/nvme and not related to hotplug
events. After the error messages are displayed, smartd cannot monitor the NVMe devices.
Workaround: It is recommended to use the nvme-cli tool to monitor the NVMe drives.
Tracking number: 169784
QLogic Gen7 Fibre Channel cards are not detected
with in-box drivers
Description:
While using the in-box drivers, QLogic 32-GFC cards are not detected. QLogic 32-GFC card details can
be identified by running the command lspci.
The output of the command is as follows:
Fibre Channel [0c04]: QLogic Corp. ISP2812-based 64/32G Fibre Channel to PCIe Controller [1077:2281]
Vendor ID: 1077
Device ID: 2281
Applies to: Red Hat Enterprise Linux 7.7
Cause: Red Hat Enterprise Linux 7.7 in-box drivers are not enabled for QLogic 32-GFC cards.
Workaround: Install out-of-box drivers.
Systems
affected:
Dell EMC PowerEdge yx4x and yx5x servers
Tracking number: 152635