Owners Manual
Table Of Contents
- Dell EMC PowerEdge Systems running Red Hat Enterprise Linux 6 (x86_64, x86) Installation Instructions and Important Information
- Installation instructions and important information
- Overview
- Latest available operating system
- System configuration requirements
- Reviewing preconfiguration options
- Installing and reinstalling Red Hat Enterprise Linux 6
- Installing Red Hat Enterprise Linux 6 using the Dell EMC Systems Management Tools and Documentation media
- Installing using the Red Hat Enterprise Linux 6 installation media
- Installing Red Hat Enterprise Linux 6 with Dell EMC Unified Server Configurator
- Installing Red Hat Enterprise Linux 6 on systems with a Dell EMC Utility Partition
- Installing Red Hat Enterprise Linux 6 in the Conventional (BIOS) Mode
- Installing Red Hat Enterprise Linux 6 in the UEFI mode
- Installing Red Hat Enterprise Linux 6 on devices that support multipathing
- Installing Red Hat Enterprise Linux 6 on iSCSI storage
- Installing Red Hat Enterprise Linux 6 using the software iSCSI initiator
- Installing Red Hat Enterprise Linux 6 using the hardware iSCSI initiator
- Installing Red Hat Enterprise Linux on FCoE-Enabled storage
- Add-on device drivers
- Updating your system packages using the Red Hat Network
- Important information
- Known issues in Red Hat Enterprise Linux 6.10
- Known issues in Red Hat Enterprise Linux 6.9
- Known issues in Red Hat Enterprise Linux 6.8
- Red Hat Enterprise Linux 6.8 does not recognize the QLogic QL45212-DE 25 GbE device
- Unable to boot Red Hat Enterprise Linux 6.7 and later from FCoE using Intel X520 based NIC
- NVMe devices are not identified during Red Hat Enterprise Linux 6.5 installation and later
- Ethtool reports 10 GbE port speed instead of 25 GbE when using Mellanox mlx5_core driver
- Resolved issues in Red Hat Enterprise Linux 6.7
- Known issues in Red Hat Enterprise Linux 6.7
- Known issues in Red Hat Enterprise Linux 6.6
- Resolved issues in Red Hat Enterprise Linux 6.6
- Kernel panic occurs when OMSA services are started on Red Hat Enterprise Linux 6.5
- Unable to Install Red Hat Enterprise Linux 6.5 with an existing brtfs partition
- Underscore is missing for the interface name of Vindicator 2 Emulex card on network page
- Unable to boot Red Hat Enterprise Linux 6.5, after successful installation in UEFI mode
- DDR DMA testing fails in ethtool on Red Hat Enterprise Linux 6.5 Hypervisor
- Using IPv6 with Mozilla Firefox displays certification error
- Data unavailability occurs on Dell EMC EqualLogic arrays due to Linux multipathing
- Red Hat Enterprise Linux 6.5 displays the error message
- Red Hat Enterprise Linux 6.5 fails to boot from iSCSI LUNs
- Known issues in Red Hat Enterprise Linux 6.5
- Booting with kernel parameters results in DMAR errors
- Xserver crashe, while booting Red Hat Enterprise Linux 6.5 after installation
- Invalid naming conventions for the ports of Vindicator 2 Emulex card when NPAR-EP is enabled
- NVMe Devices Are Not Identified During Operating System Installation
- Red Hat Enterprise Linux 6 fails when the DSDT in the BIOS has IPMI Opregion enabled
- Lifecycle Controller (USC based installation) deployment fails when installing Red Hat Enterprise Linux 6.x
- ethtool does not report 40 GB for Mellanox ConnectX-3 40 GB adapter
- Blurred display when changing resolution in Red Hat Enterprise Linux 6.5
- Resolved issues in Red Hat Enterprise Linux 6.5
- Teamed NICs have no network connectivity
- Red Hat Enterprise Linux 6.4 installation on 10 GB iSCSI LUN from an EQL array hangs while creating a file system
- Ethtool reports 10GbE port speed instead of 40GbE when using Mellanox MLX4_EN driver
- Packet loss occurs when bonding device is configured in balanced-alb mode
- Known issues in Red Hat Enterprise Linux 6.4
- Resolved issues in Red Hat Enterprise Linux 6.4
- Known issues in Red Hat Enterprise Linux 6.3
- Resolved issues in Red Hat Enterprise Linux 6.3
- Red Hat Enterprise Linux 6.2 kickstart installation may fail
- Network connections display the last used status as never in Red Hat Enterprise Linux 6
- Red Hat Enterprise Linux 6.2 displays a dbus netlink poll error after installation
- Network manager error in Red Hat Enterprise Linux 6.1 operating system log
- Red Hat Enterprise Linux 6.1 stops responding when iDRAC6 is reset
- Known issues in Red Hat Enterprise Linux 6.2
- Resolved issues in Red Hat Enterprise Linux 6.2
- Known issues in Red Hat Enterprise Linux 6.1
- Red Hat Enterprise Linux 6.1 displays a bluez network manager error after installation
- Error message on starting IPMI drivers while installing OMSA
- Assigning iSCSI LUN target to Intel 10G network controller stops the operating system from booting
- Systems with Intel multiport i350 rNDC and PCI add-in adapters report incorrect or duplicate Mac address
- tg3 driver fails post Red Hat Network update
- Kernel panic occurs when GPGPU C2075 is installed on Red Hat Enterprise Linux 6.1
- Red Hat Enterprise Linux 6.1 installation fails
- Driver installation fails during Red Hat Enterprise Linux 6.1 installation
- dmesg error log displays a generic hardware error
- Resolved issues in Red Hat Enterprise Linux 6.1
- Graphical boot splash screen in the UEFI mode is in low resolution
- PERC H700 DIMM failure messages with the debug kernel
- Network devices enumerated in an incorrect order
- OpenManage installation does not respond on Red Hat Enterprise Linux 6
- Red Hat Enterprise Linux 6 installation fails with virtual media
- Known issues in Red Hat Enterprise Linux 6
- Finding more information
- Getting help

Login using the following command fails:
#iscsiadm -m discovery -t st -p <IP> -I iface1 -o new#iscsiadm -m discovery -t
st -p <IP> -I iface1 -l
Workaround Set net.ipv4.conf.default.rp_lter to 0 or 2 in /etc/sysctl.conf, and reboot the system.
Cause In the 2.6.31 kernel, the net.ipv4.conf.default.rp_lter = 1 behavior has changed to be more strict in the I/O.
IPMI commands may result in high processor utilization
Description On PowerEdge systems that are managed through IPMI, the kipmid thread may consume high processor
resources when you issue IPMI commands to the BMC.
Workaround
Set the option kipmid_max_busy_us to the ipmi_si driver module.
This option can be set by creating a le, /etc/modprobe.d/ipmi.conf with the following line and reloading the
ipmi_si module:
options ipmi_si kipmid_max_busy_us=300
Updating rmware through Dell EMC Utility Partition may fail
in the UEFI mode
Description
When you boot to Red Hat Enterprise Linux 6 in the UEFI mode, updating the rmware through the DUP may fail
after DUP reboots the system.
Workaround Boot the system with the reboot=k kernel command line option before ashing the rmware. Add this option
to /etc/grub.conf to be persistent across reboots.
Cause
DUP relies on a warm system reset to enable rmware ashing. By default, the kernel performs a cold reset in the
UEFI mode.
A resolution for this issue will be available in a future update of the operating system.
For more information on DUP, see the Dell EMC Update Packages User’s Guide at www.dell.com/manuals.
Finding more information
• See www.dell.com/support for:
– The latest BIOS and rmware versions.
– Files that are specic to your Dell EMC hardware running the Red Hat Enterprise Linux operating system.
– Information about Dell EMC hardware that is running the Red Hat Enterprise Linux operating system.
• Additional information can be found at www.redhat.com/en/technologies/linux-platforms/enterprise-linux.
• Sign up for mailing lists at www.lists.us.dell.com.
• Search for previously posted information that addresses issues that you may encounter at www.lists.us.dell.com/pipermail/linux-
poweredge.
• For additional information, also see www.dell.com/community.
Installation instructions and important information
33