Technical Guide
Table Of Contents
- Dell EMC PowerEdge R650xs Technical Guide
- Contents
- System overview
- System features and generational comparison
- Chassis views and features
- Processor
- Memory subsystem
- Storage
- Networking
- Expansion cards and expansion card risers
- Power, thermal, and acoustics
- Rack, rails, and cable management
- Supported Operating Systems
- Dell EMC OpenManage systems management
- Dell Technologies Services
- Dell EMC ProDeploy Enterprise Suite
- Dell EMC Remote Consulting Services
- Dell EMC Data Migration Service
- Dell EMC ProSupport Enterprise Suite
- Dell EMC ProSupport Plus for Enterprise
- Dell EMC ProSupport for Enterprise
- Dell EMC ProSupport One for Data Center
- ProSupport for HPC
- Support Technologies
- Dell Technologies Education Services
- Dell Technologies Consulting Services
- Dell EMC Managed Services
- Appendix A: Additional specifications
- Appendix B. Standards compliance
- Appendix C Additional resources
Table 36. 8 x 2.5-inch SAS/SATA and 4x3.5-inch and No BP storage configuration
Dell EMC PowerEdge Server
Standard Operating Support
(ASHRAE A2 compliant) All
options supported unless
otherwise noted.
Dell EMC PowerEdge Server
Extended Inletient 40 ° C Operating Support
(ASHRAE A3 compliant)
Dell EMC PowerEdge Server
Extended Inletient 45 ° C
Operating Support (ASHRAE
A4 compliant)
thermal Spec 85C and power
<=1.2W
○ Intel Columbiaville DP
25GbE SFP28 in 8
x 2.5-inch SAS/SATA
configuration only
○ Broadcom Thor QP 25G
SFP28 in both configuration
○ Mellanox CX5 DP 25GbE
SFP28 in both configuration
○ Solarflare Medford2 DP
25GbE SFP28 in both
configuration
○ Channel Devices Intel
Columbiaville DP 25GbE in
4 x 3.5-inch SAS/SATA
configuration only (8 x 2.5-
inch SAS/SATA do not
support channel devices)
● PCIe NIC: Solarflare Medford2
DP 25GbE SFP28 only support
optic cable with thermal
Spec 85C and power <=1.2W
in 8 x 2.5-inch SAS/SATA
configuration only
● The Following PCIe NIC only
support optic cable with
thermal Spec 85C and power
<=2.5 W
○ Mellanox CX6 DP
100GbE QSFP56 in both
configuration
○ Channel Devices Intel
Columbiaville DP 100GbE
in 4 x 3.5-inch SAS/SATA
configuration only (8 x 2.5-
inch SAS/SATA do not
support channel devices)
○ Channel Devices Mellanox
CX6 100GbE in 4 x 3.5-inch
SAS/SATA configuration
only (8 x 2.5-inch SAS/
SATA do not support
channel devices
● PCIe SSD: Intel P4800X 750G
and 375G could only support
in PCIe slot2 and PCIe slot3
in 4 x 3.5-inch configs. No
restriction in 8 x 2.5-inch SAS/
SATA configuration
● The following NVMe /SAS/
SATA could not be support in
Rear Module
○ Samsung PM1735
Capacities > 6.4 TB
Appendix A: Additional specifications
55