Product Data Sheet / Brochure
Table Of Contents
- Dell EMC PowerEdge R650xs Technical Specifications
- Contents
- Technical specifications
- Chassis dimensions
- System weight
- Processor specifications
- PSU specifications
- Supported operating systems
- Cooling fans specifications
- System battery specifications
- Expansion card riser specifications
- Memory specifications
- Storage controller specifications
- Drives
- Ports and connectors specifications
- Video specifications
- Environmental specifications
Table 26. 10 x 2.5-inch NVMe and 8 x 2.5-inch NVMe configuration
Dell EMC PowerEdge Server
Standard Operating Support
(ASHRAE A2 compliant) All options
supported unless otherwise noted.
Dell EMC PowerEdge Server
Extended Inletient 40°C Operating
Support (ASHRAE A3 compliant)
Dell EMC PowerEdge Server
Extended Inletient 45°C Operating
Support (ASHRAE A4 compliant)
● 10 x 2.5-inch NVMe config Processor
TDP >220 W, RIO do not support
PCIe2
● 8 x 2.5-inch NVMe config do not
support Processor TDP >220 W
● The Following OCP3.0 NIC only
support optic cable with thermal
Spec 85C and power <=1.2W
○ Broadcom Thor QP 25G SFP28
○ Solarflare Medford2 DP 25GbE
SFP28 in both configuration
○ Channel devices Intel E810-
XXVDA4 100G 4P DPN: 6C2NG in
10x2.5 NVMe config. only (8x2.5
NVMe do not support channel
devices)
● The Following OCP3.0 NIC only
support optic cable with thermal
Spec 85C and power <=2.5W
( DPN:4WGYD)
○ Channel devices Intel E810-
CQDA2 100G QSF28 DPN:
N8PW5 in 10x2.5 NVMe config.
only (8x2.5 NVMe do not support
channel devices)
● The Following PCIe NIC only support
optic cable with thermal Spec 85C
and power <=1.2W ( DPN: M14MK)
○ Broadcom 100G 2P QSF DPN:
61PR9
○ Mellonax 25G DP OCP3 CX6 LX
SPF28 DPN: 9XCTH
○ Mellonax 25G 2P OCP3 CX6 LX
SPF28 DPN: DN78C
● The Following PCIe NIC only support
optic cable with thermal Spec 85C
and power <=2.5 W
○ Channel Devices Intel
Columbiaville DP 100GbE
○ Intel Columbiaville 100G 2P Q28
DPN: DWNRF in both configs.
● Not Support Config with RM
● Not support OCP transfer rate >25 G
or cooling tier > 10
● Optic Cable with spec 85°C is
required.
● Two PSUs are required. System
performance may be reduced in the
event of a PSU failure
Table 27. 10 x 2.5-inch NVMe storage configuration
Dell EMC PowerEdge Server
Standard Operating Support
(ASHRAE A2 compliant) All options
supported unless otherwise noted.
Dell EMC PowerEdge Server
Extended Inletient 40°C Operating
Support (ASHRAE A3 compliant)
Dell EMC PowerEdge Server
Extended Inletient 45°C Operating
Support (ASHRAE A4 compliant)
● HPR Gold fan is required
● 10 x 2.5-inch NVMe config processor
TDP > 220 W SM only support 4x2.5
NVMe at HDD#0~ HDD#3 and SM
Blank x 3 are required at HDD#4
~HDD#9.
● Not support processor TDP > 165W
● Not support BOSS M.2 Module
● Not support Non-Dell qualified
peripheral cards and Channel devices
(FW) cards
● Not support NIC consuming power
>= 25W.
● Not support processor TDP > 135 W
● Not support BOSS M.2 Module
● Not support Non-Dell qualified
peripheral cards and Channel devices
(FW) cards
● Not support NIC consuming power
>= 25 W.
Technical specifications 17