7. Press the ESC key until prompted to exit and save changes. To exit CCM,
restart the system, and apply changes, press the CTRL+ALT+DEL keys.
8. Proceed to OS installation after storage access has been provisioned in the
SAN.
Preparing Marvell Multiple Boot Agent for FCoE Boot (UEFI)
To prepare the Marvell multiple boot agent for FCOE boot (UEFI):
1. Enter the system BIOS UEFI device configuration page by pressing F2
during POST, and then select Device Settings (see Figure 6-2).
2. In the Device Settings menu (see Figure 6-3), select the desired device port.
3. In the Main Configuration Page menu, select FCoE Configuration (see
Figure 6-4).
The FCoE Boot Configuration Menu appears (see Figure 14-8).
Figure 14-8. FCoE Boot Configuration Menu
4. In the FCoE Boot Configuration menu:
a. Select Enabled for the Connect field.
b. Enter the World Wide Port Name Target.
c. Enter the Boot LUN.