Users Guide

Table Of Contents
3–QCS CLI Commands
Diagnostics
Doc No. TD-000971 Rev. 1
January 29, 2021 Page 84 Copyright © 2021 Marvell
ALL
Runs all of the preceding tests.
-l
Specifies the iteration. If not specified, the test uses the default iteration of 1.
-v
Specifies the LED interval. If not specified, the test uses the default LED interval
of 5.
Notes To stop a running test, press the CTRL+BREAK keys.
Examples The following examples show the diag command:
qcscli -t phyports -f BDF -i 04:00.00 "diag -c all -l 10 -v 5"
QLogic Control Suite Command Line Interface Utility for Windows
v17.0.7.0
.......................................................
..................................................................
Test Pass/Fail Result
---------------------------------------------------------
Control Registers 10 /0 Pass
EEPROM 10 /0 Pass
Internal Memory 10 /0 Pass
On Chip CPU 10 /0 Pass
Interrupt 10 /0 Pass
Loopback MAC 10 /0 Pass
Loopback PHY 10 /0 Pass
LED 10 /0 Pass
qcscli -t phyports -f BDF -i 04:00.00 "diag -c CPU -c LED -v 5"
QLogic Control Suite Command Line Interface Utility for Windows
v17.0.7.0
............................................................
..............................
Test Pass/Fail Result
---------------------------------------------------------
On Chip CPU 1 /0 Pass
LED 1 /0 Pass