Users Guide

Table Of Contents
B–Configuration File Examples
FCoE Boot Configuration XML File
Doc No. TD-000971 Rev. 1
January 29, 2021 Page 184 Copyright © 2021 Marvell
FCoE Boot Configuration XML File
The following sections show examples of FCoE boot configuration XML files. For
details about the command, see “Boot Configuration” on page 35.
FCoE Example Configuration File for Adapters Based on 578xx Controllers
FCoE Example Configuration File for 41000/45000 Series Adapters
FCoE Example Configuration File for Adapters Based on
578xx Controllers
<?xml version="1.0" encoding="UTF-8"?>
<FCoEBootConfiguration>
<QCScli><Version>30.0.56.0</Version></QCScli>
<FCoEGeneral>
<BoottoFCoETarget>Enabled</BoottoFCoETarget>
<TargetasFirstHDD>Disabled</TargetasFirstHDD>
<LinkUpDelayTime>0</LinkUpDelayTime>
<LUNBusyRetryCount>0</LUNBusyRetryCount>
<FabricDiscoveryTimeout>4</FabricDiscoveryTimeout>
<FCoEHBABootMode>Enabled</FCoEHBABootMode>
iSCSI Target and iSCSI Second Target Parameters
Connect Enabled | Disabled
IPAddress
IPv4 or IPv6 format IP address
TCPPort TCP port; default value is 3260
BootLun 0–65535
iSCSIName
Target IQN name
CHAPID
CHAP ID
CHAPSecret
CHAP password
a
For 41000/45000 Series Adapters, only the last saved BootProtocol setting is used.
If the
BootProtocol is set to iSCSI and the BootMode is set to Non-Offload,
set the MBA BootProtocol to iBFT. (see Table B-1 on page 177).
Table B-3. iSCSI Boot Configuration Parameters for 41000/45000
Series Adapters (Continued)
Parameter Value Range or Description