4–Using the vCenter Server Plug-in
Managing Converged Network Adapters
Doc. No. TD-000965 Rev. 1
January 21, 2021 Page 70 Copyright © 2021 Marvell
On Error: Indicate the action to take if an error occurs.
Test continuously: Select this check box to run the test continuously. Clear
the check box to run the test once only.
Click Start Test to begin the selected test. When the test is finished, the Test
Result section of the content pane shows the results.
FCoE Ping Tests
When a target with LUNs is connected to the port, you can conduct a ping test to
any target in the table. To conduct a ping test, select a target in the table, specify
the quantity of tests, and then click Start Test. The status for each test appears in
the Result column, as shown in Figure 4-44. The CT Ping and CT FC Trace
Route ping tests are conducted in a similar fashion. However, to successfully run
a CT Ping or a CT FC Trace Route ping test, the fabric must contain a Brocade
switch.
Figure 4-44. FCoE Port—Ping Test Results
Firmware Debug Dump
Click Retrieve Firmware Debug to retrieve the firmware debug dump (if it exists)
and display it in the Result area of the content pane.
NOTE
After you click Retrieve Firmware Debug, the operation may take a while to
complete.