4–Using the vCenter Server Plug-in
Managing Converged Network Adapters
Doc. No. TD-000965 Rev. 1
January 21, 2021 Page 69 Copyright © 2021 Marvell
If a target is attached to the function, the content pane also contains a table that
lists how many of each of the following errors have occurred for the target:
Link Failure
Sync Loss
Signal Loss
Invalid CRC
Seq Proto Error
Invalid Trans Word
Diagnostics Tests—FCoE Function
If the Diagnostics button is selected, the content pane appears as shown in
Figure 4-43.
Figure 4-43. Converged Network Adapter FCoE Function—Diagnostic Tests
In the content pane, select the type of diagnostic test to perform: Loopback Test,
Read-Write Buffer Test, FC Ping, CT Ping, CT FC Trace Route, or Firmware
Debug Dump. Then specify the following information:
Loopback Test and Read-Write Buffer Test
Data Pattern: Select the type of data pattern to use in the test. Or, type the
pattern to use into the boxes provided.
Number of test(s): Specify the quantity of tests to run (1–65,536).
Test Increment: Specify the test increment (1–65,536).
Data Size (Bytes): Specify the data size in bytes.