Users Guide

Table Of Contents
4–Using the vCenter Server Plug-in
Managing Fibre Channel Adapters
Doc. No. TD-000965 Rev. 1
January 21, 2021 Page 45 Copyright © 2021 Marvell
When a target with LUNs is connected to the port, you can conduct a ping test to
any target in the table. To conduct a ping test, select a target in the table, specify
the quantity of tests, and then click Start Test. The status for each test appears in
the Result column, as shown in Figure 4-17. The CT Ping and CT FC Trace
Route ping tests are conducted in a similar fashion. However, to successfully run
a CT Ping or a CT FC Trace Route ping test, the fabric must contain a Brocade
switch.
Figure 4-17. Fibre Channel Port—Ping Test Results
Retrieving Adapter Information
To view information for 2500/2600/2700 Series Adapters, select Adapter
Management, Diagnostics, then Retrieve Adapter Information.
Select one of the available buttons:
FW Table
Saves the Firmware Preload table contents to a readable text file.
NVRAM Configuration
Saves NVRAM contents to a readable text file.
SerDes Table
Saves the SerDes information to a readable text file.
NOTE
readable text filereadable text file
Information retrieved is view-only and no configuration changes can be
made.