Users Guide

Table Of Contents
10–Using the vSphere Web Client Plug-in
Managing Fibre Channel Ports
Doc. No. TD-000965 Rev. 1
January 21, 2021 Page 153 Copyright © 2021 Marvell
Data Size (Bytes)
On Error
Test continuously
6. Observe the test results.
Retrieve Firmware Debug
To retrieve the firmware debug dump:
1. In the host system tree, expand a Fibre Channel adapter node to view the
ports.
2. Select a port.
3. In the content pane, click the Diagnostics tab to open the Diagnostics page.
4. Click Retrieve Firmware Debug to retrieve the debug.bin file.
Fibre Channel Ping Tests
To perform a ping test:
1. In the host system tree, expand a Fibre Channel adapter node to view the
ports, and then select a port.
2. In the content pane, click the Diagnostics tab to open the Diagnostics page.
3. In the Ping Tests table, select a target. To choose multiple targets, hold
down the CTRL key while you click additional targets.
4. Click either Start FC Ping, Start CT Ping, or Start CT FC Trace Route to
start the appropriate test. To successfully run a CT Ping or a CT FC Trace
Route ping test, the fabric must contain a Brocade switch.
5. In the Ping Test dialog box, specify the quantity of tests, and then click OK.