Users Guide

Table Of Contents
5–Managing Marvell 578xx and 41000 Series Adapters
Configuring Port Boot Options
Doc. No. TD-000965 Rev. 1
January 21, 2021 Page 106 Copyright © 2021 Marvell
4. Complete the following in the Configure MPIO Parameters pane:
a. Select the Enable MPIO check box to enable MPIO, or clear the check
box to disable it.
b. Select a MAC address from an adapter (or select None) for the
Secondary Device.
c. Select the Use Independent Target Portal check box to enable the
use of independent target portal, or clear the check box it to disable it.
d. Select the Use Independent Target name check box to enable the
use of independent target name, or clear the check box to disable it.
5. Click Save.
Figure 5-11 shows the Configure MPIO Parameters section in the iSCSI Boot
Configuration window for 578xx Series Adapters.
Figure 5-11. iSCSI Boot Configuration Pane for 578xx Series Adapters
Configuring FCoE Boot
This section describes how to configure general and target FCoE boot.
Configuring General Parameters
To configure the FCoE general parameters:
1. In the QConvergeConsole system tree, select an adapter, and then select
the appropriate port.
2. In the content pane on the right, click Boot Configuration.
3. Click the FCoE Boot button.