5–Managing Marvell 578xx and 41000 Series Adapters
Configuring Port Boot Options
Doc. No. TD-000965 Rev. 1
January 21, 2021 Page 105 Copyright © 2021 Marvell
4. Under Configure Primary Target Parameters, complete the following:
a. Select the Connect check box to enable connect, or clear the check
box to disable it.
b. Type the IP address in the IP Address box.
c. Type a value in the TCP Port box.
d. Type a value in the Boot LUN box.
e. Type the iSCSI name in the iSCSI Name box.
f. Type the CHAP ID in the CHAP ID box.
g. Type the CHAP secret key in the CHAP Secret box.
h. Complete Step 5 as needed.
5. Under Configure Secondary Target Parameters, complete the following:
a. Select the Connect check box to enable connect, or clear the check
box to disable it.
b. Type the IP address in the IP Address box.
c. Type a value in the TCP Port box.
d. Type a value (from 0 to 255) in the Boot LUN box.
e. Type the iSCSI name in the iSCSI Name box.
f. Type the CHAP ID in the CHAP ID box.
g. Type the CHAP secret key in the CHAP Secret box.
6. Click Save.
Figure 5-11 on page 106 shows the Configure Primary Target Parameters and
Configure Secondary Target Parameters section in the Configure iSCSI Boot
Parameters window.
Configuring MPIO Parameters
To configure the MPIO parameters:
1. Select the appropriate port in the QConvergeConsole system tree.
2. Click Boot Configuration.
3. Click the iSCSI Boot option.
NOTE