Users Guide

Table Of Contents
5–Fibre Channel Noninteractive Commands
-n (Configure HBA Parameters)
Doc. No. TD-000947 Rev. 1
Janurary 29, 2021 Page 71 Copyright © 2021 Marvell
-n (Configure HBA Parameters)
To set a specific parameter on a specific adapter port, issue the following
command:
qaucli -n <hba instance>|<hba wwpn> <param name> <param value>
To restore the factory default adapter parameters, issue the following command:
qaucli -n <hba instance>|<hba wwpn> <param alias> <param value>
To update the adapter port parameters using a predefined OEM default template,
issue the following command:
qaucli -n <hba instance>|<hba wwpn>|all <default>
Where:
The pairs <param name> <param value> and <param alias> <param
value> can be repeated to set multiple parameters with a single command.
Table 5-9 lists the adapter parameter names and aliases, alphabetized by name.
.
<hba instance> = Adapter number (use the -g command to find)
<hba wwpn> = World wide port name of the adapter
<param name> = Name of the parameters
<param alias> = Alias of the parameters
<param value> = New value of the parameters
<default> = One of the following OEM names:
EMC = EMC-specific settings
HP = HP-specific settings
IBM = IBM
®
-specific settings
QLGC = Marvell-specific settings
SUN = Sun
®
or Oracle-specific settings
Table 5-9. Adapter Parameters
Description Name Alias Value
Connection options
ConnectionOption
a
CO 0 = Loop only
1 = Point-to-point only
2 = Loop preferred, otherwise
point-to-point
3 = Point-to-point preferred,
otherwise loop