Users Guide

Table Of Contents
5–Fibre Channel Noninteractive Commands
-l (FC Target/LUN Information)
Doc. No. TD-000947 Rev. 1
Janurary 29, 2021 Page 65 Copyright © 2021 Marvell
If the read/write buffer test fails, the system shows the following information:
Loop or port ID (the loop ID of the adapter when operating in loop mode).
Status:
Success—The test passed.
Error—A data miscompare or link status firmware error occurred.
Failed—A link status error, SCSI write buffer error, or SCSI read buffer
error occurred.
Unknown—The target was not present.
Unsupported—The device does not support this test.
Data Miscompare—The possible values are:
0 (no data miscompares)
Device not present
Get link status failed
Read buffer failed
R/W buffer not supported
Write buffer failed
Link Failure—Number of link failures
Loss of sync—Number of sync loss errors
Loss of signal—Number of signal loss errors
Invalid CRC—Number of invalid CRCs
-l (FC Target/LUN Information)
The -l command shows LUN information for:
All adapters
A specific target
A specific LUN on a specific target
To show the LUN information for all target devices for a specific adapter Instance,
issue the following command:
qaucli -pr fc -l <hba instance>|<hba wwpn>
Table 5-7. Data Pattern (DP) Test Patterns
Hex Binary Hex Binary
00 00000000 A5 10100101
55 01010101 AA 10101010
5A 01011010 FF 11111111