Users Guide

Table Of Contents
5–Fibre Channel Noninteractive Commands
-dp (Diagnostic Port Test)
Doc. No. TD-000947 Rev. 1
Janurary 29, 2021 Page 37 Copyright © 2021 Marvell
Media Information
------------------------------------------------------------------
Vendor: FINISAR CORP.
Type: 800-M5-SN-S
Part Number: FTLF8532P4BCV-QL
Speed: 3200 MBytes/Sec 1600 MBytes/Sec 800 MBytes/Sec
Revision: A
Serial Number: UV41BT2
-dp (Diagnostic Port Test)
Information about this command will be provided in a future version of this guide.
-dport (Diagnostics Port)
Use the -dport command to identify and isolate link failures resulting from
faulty modules (link, cable, or SFP).
To display current diagnostics port option, issue the following command:
qaucli.exe -dport <hba instance>|<hba wwpn> --info [<port_option>]
To enable the diagnostics port test, issue the following command.
qaucli.exe -dport <hba instance>|<hba wwpn> --enable
[<port_option>]
To run diagnostics port test, issue the following command:
qaucli.exe -dport <hba instance>|<hba wwpn> --show [<port_option>]
To disable diagnostics port test, issue the following command:
qaucli.exe -dport <hba instance>|<hba wwpn> --disable
[<port_option>]
Where:
NOTE
d ed
This feature is supported only with 16G/32G Fibre Channel adapters and
requires supported Brocade switches with the appropriate license.
<hba instance> = Adapter number (use the -g command to find)
<hba wwpn> = World wide port name of the adapter
<all> = All discovered adapters.