Users Guide

Table Of Contents
6–Fibre Channel Interactive Commands
FC Ping Test
Doc. No. TD-000947 Rev. 1
Janurary 29, 2021 Page 183 Copyright © 2021 Marvell
-------- ------------------- ---------------- ------------
Value 01 0xD2 0xD3 0xD5
Status 0x01 0x01 0x01 0x02
Result Passed Passed Passed Skipped
Details: 0x0
Details: 0x0
FC Ping Test
4. Adapter Diagnostics2. Fibre Channel Adapter11. FC Ping Test
From the FC Adapter Diagnostics menu, select the FC Ping Test option. The FC
Ping Test menu opens and lists options to display, reset, and configure ping test
parameters, and to run the FC ping test.
Display Test Parameters
4. Adapter Diagnostics2. Fibre Channel Adapter11. FC Ping Test 1. Display Test Parameters
From the FC Ping Test menu, select Display Test Parameters to view the current
diagnostics settings. For example:
------------------------------------------------------------------------------
HBA Instance 0: QLE2740 Port 1 WWPN 21-00-00-24-FF-00-27-D5 PortID 02-05-00
Link: Online (FEC)
------------------------------------------------------------------------------
--------------------
Diagnostics Settings
--------------------
Diagnostic Mode : FC Ping ELS Echo
Destination WWN : 10-00-00-27-F8-F1-66-A0
Data Pattern : Random (RPAT)
Data Size (Bytes) : 8
Number of Echo Request : 1
Wait Interval (Seconds) : 1
Abort On Error : Ignore
------------------------------------------------------------------------------
Reset Test Parameters
4. Adapter Diagnostics2. Fibre Channel Adapter11. FC Ping Test 2. Reset Test Parameters
From the FC Ping Test menu, select Reset Test Parameters to return the FC
ping test parameters to their default values.