6–Fibre Channel Interactive Commands
Diagnostics Port Test (-dport)
Doc. No. TD-000947 Rev. 1
Janurary 29, 2021 Page 181 Copyright © 2021 Marvell
Seq Proto Error
Invalid Trans Word
Run
4. Adapter Diagnostics2. Fibre Channel Adapter9. Link Status4. Run
From the FC Diagnostics menu, select the Link Status option, and then select
Run to start running a link status. Press ENTER to stop running the link status.
---------------------------------------
Link Status Settings
---------------------------------------
AutoPoll (AP): 10
SetRate (SR): 5
LogToFile (LF): null.csv
--------------------------------------------------------------------------------
HBA Instance 1: QLE2662 Port 2 WWPN 20-01-00-09-0C-00-FF-01 PortID 00-00-00
Link: SFP not installed
--------------------------------------------------------------------------------
Link Status
-------------------------------------------
General keyboard shortcuts:
R - Reset current
C - Refresh current
T - Refresh total
ENTER - Cancel the current task
-------------------------------------------
Port Name Link Sync Signal Invalid Seq Proto Invalid
Failure Loss Loss CRC Error Trans Word
----------------------- -------- -------- -------- -------- --------- ----------
20-01-00-09-0C-00-FF-01 0 0 0 0 0 0
--------------------------------------------------------------------------------
Diagnostics Port Test (-dport)
4. Adapter Diagnostics2. Fibre Channel Adapter10. Diagnostics Port Test
From the FC Adapter Diagnostics menu, select the Diagnostics Port Test option,
and then select a port with a link speed of 16Gbps or 32Gbps. The Diagnostics
Port Menu opens and lists options to configure and run port, electrical and optical
loopback, and link traffic diagnostics on the selected port. This option is not
supported on the Oracle Solaris platform.