Users Guide

Table Of Contents
6–Fibre Channel Interactive Commands
CT Ping Test (-ctp)
Doc. No. TD-000947 Rev. 1
Janurary 29, 2021 Page 174 Copyright © 2021 Marvell
-----------------------------------------------------------------------------
Diagnostics Settings
--------------------
Diagnostic Mode : CT Ping
Number of tests (1-10000): 10
Test Increment(1-10000) : 1
Abort On Error : Ignore
Test Continuous : OFF
-----------------------------------------------------------------------------
Reset Test Parameters
4. Adapter Diagnostics2. Fibre Channel Adapter7. CT Ping Test2. Reset Test Parameters
From the CT Ping Test menu, select the Reset Test Parameters option to reset
the CT ping test parameters to the default values.
Configure Test Parameters
4. Adapter Diagnostics2. Fibre Channel Adapter7. CT Ping Test3. Configure Test Parameters
From the CT Ping Test menu, select the Configure Test Parameters option to
open the CT Ping Test submenu. The CT Ping Test menu lists options to configure
the quantity of tests and test increments, set abort on error, and enable or disable
devices. For detailed information about these parameters, see Table 5-3 on page
35.
For example:
=======================================================
HBA : 4 Port: 1
SN : AFD1915Y07299
HBA Model : QLE2772
HBA Desc. : QLogic QLE2772 2x32Gb QLE2772 FC HBA
FW Version : 9.06.02
WWPN : 21-00-F4-E9-D4-54-AB-12
WWNN : 20-00-F4-E9-D4-54-AB-12
Link : Online (FEC)
=======================================================
1: Number Of Test(s)
2: Test Increment(s)
3: Test Option
4: Enable/Disable Device(s)