6–Fibre Channel Interactive Commands
CT Ping Test (-ctp)
Doc. No. TD-000947 Rev. 1
Janurary 29, 2021 Page 172 Copyright © 2021 Marvell
---------------------------------------------------
Diagnostic Mode : FC Ping
Number of tests (1-10000): 10
Number of Pass : 1
Test Increment(1-10000) : 1
Abort On Error : Ignore
Test Continuous : OFF
--------------------------------------------------------------------------------
--------- ---------- ---------- ---------- ---------- ---------- ---------------------
ID Data Link Sync Signal Invalid Diagnostics
Port/Loop Miscompare Failure Loss Loss CRC Status
--------- ---------- ---------- ---------- ---------- ---------- ---------------------
01-29-05 0 0 0 0 0 10 replies in 3 ms
01-29-04 0 0 0 0 0 10 replies in 3 ms
CT Ping Test (-ctp)
4. Adapter Diagnostics2. Fibre Channel Adapter7. CT Ping Test
From the FC Adapter Diagnostics menu, select the CT Ping Test option, and then
select a port. The CT Ping Test menu opens and lists options to view, reset, and
configure common transport (CT) ping test parameters, and to start the CT ping
test.
For example:
QConvergeConsole
CLI - Version x.y.z (Build xx)
FC Diagnostics
HBA Model QLE2772 SN: AFD1915Y07299
1: Port 1: WWPN: 21-00-F4-E9-D4-54-AB-12 Online (FEC)
2: Port 2: WWPN: 21-00-F4-E9-D4-54-AB-14 Online (FEC)
HBA Model QLE2562 SN: GFC0819H89417
3: Port 1: WWPN: 21-00-00-1B-32-0C-A9-0B SFP not present
4: Port 2: WWPN: 21-01-00-1B-32-2C-A9-0B SFP not present
HBA Model QLE2672 SN: RFE1303H21665
NOTE
Currently, only Brocade switches support the CT Ping Test.