Users Guide

Table Of Contents
6–Fibre Channel Interactive Commands
Transceiver Diagnostics Monitoring Interface (DMI)
Doc. No. TD-000947 Rev. 1
Janurary 29, 2021 Page 164 Copyright © 2021 Marvell
For example:
FC/FCoE Read/Write Buffer Test
=======================================================
HBA : 1 Port: 2
SN : AFD1536Y03145
HBA Model : QLE2692
HBA Desc. : QLE2692 Dual Port 16Gb FC to PCIe Gen3 x8 Adapter
FW Version : 8.05.41
WWPN : 21-00-00-24-FF-8F-D8-67
WWNN : 20-00-00-24-FF-8F-D8-67
Link : D-Port
=======================================================
1: Data Patterns
2: Data Size
3: Number Of Test(s)
4: Test Increment(s)
5: Abort On Error
6: Enable/Disable Device(s)
Start Diagnostics Test (-kr)
4. Adapter Diagnostics2. Fibre Channel Adapter2. Read Write Buffer Test<port selection>4. Start Diagnostics
Test
From the Read Write Buffer Test menu, select the Start Diagnostics Test option
to run the read write buffer test.
Transceiver Diagnostics Monitoring Interface (DMI)
4. Adapter Diagnostics2. Fibre Channel Adapter3. Transceiver Diagnostics Monitoring Interface (DMI)
From the FC Adapter Diagnostics menu, select the Transceiver Diagnostics
Monitoring Interface (DMI) option. From the port menu, select a port to open the
Transceiver Diagnostics Monitoring Interface (DMI) menu with options to view
general and detailed transceiver information. For example:
FC Adapter Diagnostics
HBA Model QLE2692 SN: GFC0718P57753
1: Port 1: WWPN: 21-00-00-1B-32-17-F9-C4 Online
2: Port 2: WWPN: 21-01-00-1B-32-37-F9-C4 Loop Down
(p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit)
Please Enter Selection: 1