Users Guide

Table Of Contents
6–Fibre Channel Interactive Commands
Read Write Buffer Test (-kr)
Doc. No. TD-000947 Rev. 1
Janurary 29, 2021 Page 163 Copyright © 2021 Marvell
Display Test Parameters (-kr)
4. Adapter Diagnostics2. Fibre Channel Adapter2. Read Writer Buffer Test<port selection>1. Display Test
Parameters
From the Read Write Buffer Test menu, select the Display Test Parameters
option to view the read write buffer test parameters. For example:
------------------------------------------------------------------
HBA Instance 1: QLE2692 Port 2 WWPN 21-00-00-24-FF-8F-D8-67 PortID
00-00-00
Link: D-Port
------------------------------------------------------------------
--------------------
Diagnostics Settings
--------------------
Diagnostic Mode : R/W Buffer
Data Pattern : Random
Data Size (Bytes) : 8
Number of tests (1-10000): 10
Test Increment(1-10000) : 1
Abort On Error : Ignore
Test Continuous : OFF
------------------------------------------------------------------
Reset Test Parameters
4. Adapter Diagnostics2. Fibre Channel Adapter2. Read Write Buffer Test<port selection>2. Reset Test
Parameters
From the Read Write Buffer Test menu, select the Reset Test Parameters option
to reset the read write buffer test parameters to their default values.
Configure Test Parameters (-kr)
4. Adapter Diagnostics2. Fibre Channel Adapter2. Read Write Buffer Test<port selection>3. Configure Test
Parameters
From the Read Write Buffer Test menu, select the Configure Test Parameters
option to open the Read Write Buffer Test submenu with options to configure the
data pattern, data size, number of tests, test increment, error handling, and
devices. For detailed information about these parameters, see Table 5-6 on page
64.