Start Diagnostics Test
4. Adapter Diagnostics2. Fibre Channel Adapter1. Loopback Test<port selection>4. Start Diagnostics Test
From the Loopback Test menu, select the Start Diagnostics Test option to run
the external loopback test. For example:
------------------------------------------------------------------------------
HBA Instance 0: QLE2692 Port 1 WWPN 21-00-00-24-FF-8F-D8-66 PortID 01-0A-00
Link: Online
------------------------------------------------------------------------------
--------------------
Diagnostics Settings
--------------------
Diagnostic Mode : Loopback
Data Pattern : Random
Data Size (Bytes) : 8
Number of tests (1-65535): 10
Test Increment(1-65535) : 1
Abort On Error : Ignore
Test Continuous : OFF
Loopback Type : External Loopback
------------------------------------------------------------------------------
----------------------------------
Diagnostics - Loopback Test Result
----------------------------------
Press <Enter> to abort
---------------------------------------------
HBA Test Data Pattern Status CRC Disparity FrameLength
--- ----------------------- ----------- --------- --------- -----------
0 2B-12-30-2F-5C-35-44-01 Success 0 0 0
Finished 10 iterations in 0 second(s)...