Users Guide

Table Of Contents
5–Fibre Channel Noninteractive Commands
-tm (Temperature Monitor)
Doc. No. TD-000947 Rev. 1
Janurary 29, 2021 Page 92 Copyright © 2021 Marvell
qaucli -tm <hba instance> | <hba wwpn> | <all>
{<param name>|<param alias>
<param value>}
Where:
<hba instance>
=
Adapter number (use the -g command to find)
<hba wwpn>
=
World wide port name of the adapter
<all>
=
All discovered adapters
<param name>
=
One of the following parameter names:
AutoPoll
SetRate
LoAlarm
HiAlarm
LogToFile
<param alias>
=
One of the following parameter aliases:
AP
SR
LO
HI
LF
<param value>
=
Value of parameter or alias (see Tab le 5- 1 0)
Table 5-10. Temperature Monitor Parameters
Parameter
Name
Parameter
Alias
Value Description
AutoPoll AP 0
1–256
Set to automatically read the temperature of all
adapters.
Set to manually read the temperature of all adapters
updated at the given iteration.
SetRate SR 5–300 Set the polling interval during automatic update (in
seconds).
LoAlarm LO 0–5 Alert when the temperature is below this threshold
value.
HiAlarm HI 1–100 Alert when the temperature exceeds this threshold
value.
LogToFile LF File name Export temperature monitored data to a CSV file.