Users Guide

Table Of Contents
5–Fibre Channel Noninteractive Commands
-rdp (Read Diagnostics Parameter)
Doc. No. TD-000947 Rev. 1
Janurary 29, 2021 Page 85 Copyright © 2021 Marvell
Attached FC Port Buffer To Buffer Credits: 372
Nominal FC Port RTT: 0 ns
---------------------------------
Optical Product Data Descriptor
---------------------------------
Descriptor Tag: Optical Product Data
Descriptor Length: 60 Bytes
Vendor Name: BROCADE
Part Number: 57-0000088-01
Serial Number: HAA11126100P8L2
Revision:
Date: 110628
---------------------------------
Optical Element Data Descriptor
---------------------------------
Descriptor Tag: Optical Element Data
Descriptor Length: 12 Bytes
Temperature High Alarm: 0x55
Temperature High Alarm: 85.00
Temperature Low Alarm: 0xfffb
Temperature Low Alarm: -5.00
Temperature High Warning: 0x4b
Temperature High Warning: 75.00
Temperature Low Warning: 0x00
Temperature Low Warning: 0.00
---------------------------------
Optical Element Data Descriptor
---------------------------------
Descriptor Tag: Optical Element Data
Descriptor Length: 12 Bytes
Voltage High Alarm: 0x8ca0
Voltage High Alarm: 3.60
Voltage Low Alarm: 0x7530