Users Guide
3–Adapter Management Applications
Windows Management Applications
99 CU0354602-00 M
For every test performed, the diagnostic utility shows the following data:
Total number of attempts
Number of successful completions
Number of failures
You can either perform all tests in succession or perform only specific tests
specified by the preceding command-line parameters.
You can run additional diagnostics in the CLI as listed in the following table. To
determine the cna_port_inst, issue the qaucli -nic –i command as
shown in Table 3-8.
-nL
--noIntLP
No internal loopback test (combine –D or –a)
-nH
--noHw
No hardware test (combine –D or –a)
-nS
--noLinkSt
No link status test (combine –D or –a)
-h
--help
View help text
a
All commands must be prefaced by qaucli -pr nic -qldiag. For example, to view the help,
issue the following commands:
qaucli -pr nic -qldiag --help
Table 3-8. Running Windows Diagnostic Tests in the CLI
Test Type Command
External
Loopback
qaucli -nic -extloopback <cna_port_inst> <tests_num> <on_error>
where <tests_num> specifies the number of tests, 1–65535, and <on_error> is
either 0=Ignore or 1=Abort.
NOTE:
This test requires a pass-through module to be configured for both ports. Test runs
between two ports. Single port loopback is not supported
.
Flash qaucli –nic –testflash [cna_port_inst]
Hardware qaucli –nic –testhw [cna_port_inst]
Internal
Loopback
qaucli -nic -intloopback <cna_port_inst> <tests_num> <on_error>
where <tests_num> specifies the number of tests, 1–65535, and <on_error> is
either 0=Ignore or 1=Abort.
Interrupt qaucli –nic –testinterrupt [cna_port_inst]
Table 3-7. Diagnostic Test Commands (Continued)
Command
a
Description