Users Guide
11–Configuración FCoE
Configuración de la descarga FCoE de Linux
236 AH0054602-09 M
[ 235.322253] [0000:21:00.2]: [__qedf_probe:3142]:4: QLogic FastLinQ FCoE
Module qedf 8.18.8.0, FW 8.18.10.0
[ 235.606443] scsi host4: qedf
....
[ 235.624337] [0000:21:00.3]: [__qedf_probe:3142]:5: QLogic FastLinQ FCoE
Module qedf 8.18.8.0, FW 8.18.10.0
[ 235.886681] scsi host5: qedf
....
[ 243.991851] [0000:21:00.3]: [qedf_link_update:489]:5: LINK UP (40 GB/s).
3. Compruebe los dispositivos FCoE detectados mediante los comandos
lsscsi
o lsblk -S. A continuación, un ejemplo de cada comando.
# lsscsi
[0:2:0:0] disk DELL PERC H700 2.10 /dev/sda
[2:0:0:0] cd/dvd TEAC DVD-ROM DV-28SW R.2A /dev/sr0
[151:0:0:0] disk HP P2000G3 FC/iSCSI T252 /dev/sdb
[151:0:0:1] disk HP P2000G3 FC/iSCSI T252 /dev/sdc
[151:0:0:2] disk HP P2000G3 FC/iSCSI T252 /dev/sdd
[151:0:0:3] disk HP P2000G3 FC/iSCSI T252 /dev/sde
[151:0:0:4] disk HP P2000G3 FC/iSCSI T252 /dev/sdf
# lsblk -S
NAME HCTL TYPE VENDOR MODEL REV TRAN
sdb 5:0:0:0 disk SANBlaze VLUN P2T1L0 V7.3 fc
sdc 5:0:0:1 disk SANBlaze VLUN P2T1L1 V7.3 fc
sdd 5:0:0:2 disk SANBlaze VLUN P2T1L2 V7.3 fc
sde 5:0:0:3 disk SANBlaze VLUN P2T1L3 V7.3 fc
sdf 5:0:0:4 disk SANBlaze VLUN P2T1L4 V7.3 fc
sdg 5:0:0:5 disk SANBlaze VLUN P2T1L5 V7.3 fc
sdh 5:0:0:6 disk SANBlaze VLUN P2T1L6 V7.3 fc
sdi 5:0:0:7 disk SANBlaze VLUN P2T1L7 V7.3 fc
sdj 5:0:0:8 disk SANBlaze VLUN P2T1L8 V7.3 fc
sdk 5:0:0:9 disk SANBlaze VLUN P2T1L9 V7.3 fc
La información de configuración del host está ubicada en
/sys/class/fc_host/hostX,
donde X es el número del host SCSI. En el
ejemplo anterior,
X es 4. El archivo hostX contiene atributos de la función
FCoE, como el nombre de puerto mundial y el Id. de estructura.