Users Guide

5–Adapter Preboot Configuration
Configuring FCoE Boot
55 AH0054602-00 M
Configuring FCoE Boot
To configure the FCoE boot configuration parameters:
1. On the Main Configuration Page, select FCoE Configuration, and then
select the following as needed:
FCoE General Parameters (Figure 5-9)
FCoE Target Configuration (Figure 5-10)
2. Press ENTER.
3. Choose values for the FCoE General or FCoE Target Configuration
parameters.
Figure 5-9. FCoE General Parameters
NOTE
The FCoE Boot Configuration Menu is only visible if FCoE Offload Mode is
enabled on the second partition in NPAR mode (see Figure 5-18 on page
64). It is not visible in non-NPAR mode.
To enable FCoE-Offload mode, see the Application Note, Enabling Storage
Offloads on Dell and Marvell FastLinQ 41000 Series Adapters at
https://www.marvell.com/documents/5aa5otcbkr0im3ynera3/
.